An optional radio frequency module and a remote antenna can be installed if the residents will access a controlled area with a transmitter. Refer to instructions supplied with the optional RF Module for more information.
NOTE: The remote can control
RF Module(s) will fit in positions J400 (Device 1) and/or J407 (Device 3)
(4 Mounting Screws per Board are Required)
| Avoid any metallic | |
| surface around the | |
Coaxial |
| antenna. |
Connector |
|
|
| 1 RF Module Kit |
|
| Part # RFMODKT |
|
| (390 MHz) |
|
| or |
|
| Part # RFMODKT3 | Remote Antenna |
| (315 MHz) | |
|
| |
|
| |
| 100 Feet Maximum |
|
Wiegand card readers and keypads can be connected to either of 2 optional Wiegand modules that can be placed in the unit. Each Wiegand module supports two card readers/keypads. Some Wiegand card reader/keypads have a sixth blue wire. DO NOT connect this blue wire to the unit. Insulate this wire from the unit to prevent a short (Refer to instructions supplied with your Wiegand device for more information).
J407 Position | J400 Position |
|
| |||
Device 4 | Device 3 | Device 2 | Device 1 |
|
| |
P12V | COM | P12V | COM | Black | Use | |
Brown | ||||||
P5V | LED | P5V | LED | AWG | ||
White | ||||||
DATA 0 DATA 1 | DATA 0 DATA 1 |
| ||||
Green |
| |||||
DATA 1 DATA 0 | DATA 1 DATA 0 | Card Reader is Wired to Device 1 | ||||
| ||||||
LED | P5V | LED | P5V | Red Power |
| |
COM | P12V | COM | P12V | Blue (Insulate this wire). | ||
| ||||||
J2 | J1 | J2 | J1 |
|
|
Shield (Attach to the unit ground only).
| Wiegand Modules will fit in | |
| J400 as Device 1 (J1) and 2 (J2) | |
| and/or | |
1 Wiegand Module Kit | J407 as Device 3 (J1) and 4 (J2) | |
(4 Mounting Screws per Board are Required) | ||
Part # WOMODKT | ||
|
Page 18