Wiring a Radio Frequency Module

An optional radio frequency module and a remote antenna can be installed if the residents will access a controlled area with a transmitter. Refer to instructions supplied with the optional RF Module for more information.

Reader / Keypad

NOTE: The remote can control 1-4 doors.

RF Module(s) will fit in positions J400 (Device 1) and/or J407 (Device 3)

(4 Mounting Screws per Board are Required)

RG-6

 

Avoid any metallic

 

surface around the

Coaxial

 

antenna.

Connector

 

 

 

1 RF Module Kit

 

 

Part # RFMODKT

 

 

(390 MHz)

 

 

or

 

 

Part # RFMODKT3

Remote Antenna

 

(315 MHz)

 

 

 

RG-6 Coaxial Cable

 

 

100 Feet Maximum

 

Wiring a RF Module / Card
Wiegand Card Reader/Keypad

Wiegand card readers and keypads can be connected to either of 2 optional Wiegand modules that can be placed in the unit. Each Wiegand module supports two card readers/keypads. Some Wiegand card reader/keypads have a sixth blue wire. DO NOT connect this blue wire to the unit. Insulate this wire from the unit to prevent a short (Refer to instructions supplied with your Wiegand device for more information).

J407 Position

J400 Position

 

 

Device 4

Device 3

Device 2

Device 1

 

 

P12V

COM

P12V

COM

Black

Use 18-24

Brown

P5V

LED

P5V

LED

AWG

White

DATA 0 DATA 1

DATA 0 DATA 1

 

Green

 

DATA 1 DATA 0

DATA 1 DATA 0

Card Reader is Wired to Device 1

 

LED

P5V

LED

P5V

Red Power

 

COM

P12V

COM

P12V

Blue (Insulate this wire).

 

J2

J1

J2

J1

 

 

Shield (Attach to the unit ground only).

 

Wiegand Modules will fit in

 

J400 as Device 1 (J1) and 2 (J2)

 

and/or

1 Wiegand Module Kit

J407 as Device 3 (J1) and 4 (J2)

(4 Mounting Screws per Board are Required)

Part # WOMODKT

 

Page 18