Wiring a Door Strike Lock
Output Board (See page 6)
DO NOT overload the removable terminal block connectors. One wire per hole.
RES
Board Output IO
| NO |
| LED 4 |
J5 | NC |
| C |
| RELAY 4 |
| NO |
J4 | NC |
| LED 3 |
| C |
AC or DC Power for Door Strike (Not Provided)
DO NOT use the unit’s power supply for the Door Strike.
Normally Open
For DC Power: Install a 1N4005 diode or equivalent.
– +
J6
TELCO
For AC Power: Install a Siemens S10K30 MOV (Metal Oxide Varistor)or
equivalent. J8
Common
Use
NOTE: The door strike can be connected to any of the 4 relays.
| RELAY 3 |
| NO |
J3 | NC |
| C |
| LED 2 |
| NO |
| RELAY 2 |
| NC |
J1 | C |
| |
| LED 1 |
| RELAY 1 |
Door a Wiring
Wiring a Maglock
Strike
Install a 1N4005 diode or |
equivalent. |
RES
J6
For AC Power: Install a Siemens S10K30 MOV (Metal Oxide Varistor)TELCOor equivalent.
Board Output IO
Output Board (See page 6)
| NO |
| LED 4 |
J5 | NC |
| C |
| RELAY 4 |
| NO |
J4 | NC |
| LED 3 |
| C |
| RELAY 3 |
| NO |
J3 | NC |
| C |
| LED 2 |
| NO |
Lock/Maglock
AC or DC |
Power for |
| + |
Door Strike | – | |
(Not Provided) |
|
Normally Closed
Use
Common
J8
| RELAY 2 |
| NC |
J1 | C |
|
DO NOT use the unit’s power supply for the Maglock.
NOTE: The maglock can be connected to any of the
4 Relays.
LED 1 |
RELAY 1 |
Page 15