Wiring a Postal Lock Switch - EL25 Models Only

The Post Office requires installation of a postal lock if postal carriers do not have access to a controlled area. Contact the local post office and arrange for them to install the postal lock while you are on site. The postal lock requires a switch to activate one of the four relays (Configurable with programming number 69 , in the Keypad Programming Manual).

J7

Wiring

In

J6

POSTAL

J3

Common

 

Use

18-24 AWG

AUTO

J2

J5

 

J1 POWER 12VAC/DC

J4

IO Input Board

Input Board

(See page 6)

N.C.

Switch

DO NOT overload the removable terminal block connectors. One wire per hole.

Lock Postal a

NOTE: In the EL2000 models, the postal lock switch is pre-wired.

Wiring an Internal Camera [CCTV]

An Optional CCTV (Close Circuit Television) camera can be installed inside the unit. Refer to instructions supplied with the camera kit for more information.

Contact your dealer/ installer for more information

Home Entertainment

System

OR

RG-59u Coaxial Cable 1000 Feet Maximum

(Monitor with a .25 volt p-p composite signal sensitivity)

EL25

EL2000

A Closed Circuit Monitor

(CCTV) Camera Internal / Switch

Page 19