Wiring a Gate Operator
Switch / PIR / REX

DO NOT overload the removable terminal block connectors. One wire per hole.

Output Board

(See page 6)

RES

J6

TELCO

Normally Open

J8

Common

Use 18-24 AWG

NOTE: The gate operator can be connected to any of the 4 relays.

Board Output IO

 

NO

 

LED 4

J5

NC

 

C

 

RELAY 4

 

NO

J4

NC

 

LED 3

 

C

 

RELAY 3

 

NO

J3

NC

 

C

 

LED 2

 

NO

 

RELAY 2

 

NC

J1

C

 

 

LED 1

 

RELAY 1

Operator / Key

NOTE: Refer to your gate operators owner’s manual for proper relay strike time.

Wiring a Key Switch/PIR/REX

Any auxiliary opening device such as a key switch or PIR (Passive Infrared Device), or an exit request button (REX) that provides normally open contact closure can be hooked up to the Door Input terminals.

Wiring a Gate

 

 

Input Board

 

 

(See page 6)

EXIT

 

 

REQ 4

 

 

COM

J7

 

DOOR

 

 

STAT 4

 

 

EXIT

 

 

REQ 3

 

 

COM

J6

POSTAL

DOOR

 

 

 

STAT 3

 

 

EXIT

 

 

REQ 2

 

AUTO

COM

J5

 

DOOR

STAT 4

EXIT

REQ 1

COM

DOOR

STAT 1

NOTE: Additional opening or exit devices can be connected to any of the 4 Exit Request inputs.

J3

J2

J1

Exit Request

 

12VAC/DC

 

IO Input Board

Common

 

 

Use 18-24 AWG

Page 16