APPENDIX A

SYSTEM OPERATION REFERENCE

CONTROLS, INDICATORS, INPUTS AND ADJUSTMENTS

For control and indicator locations, refer to Figure 11. For detailed explanations of the Gate Operator's various, controls, indicators, inputs and adjustments, refer to the following pages.

CONTROLS
KEYPAD

The 12-key keypad is used for local operation, programming and

 

service.

SWITCH S2

 

GATE OPEN TO

Selects the direction the gate will open (LEFT/RIGHT).

LEFT/RIGHT

 

SWITCH S3

 

LOW BATTERY

Selects the direction the gate will move and remain when the LOW

LEFT/RIGHT

BATTERY input is activated by an Uninterruptible Power Supply (UPS).

INDICATORS

LED indicators light when controls and inputs are active. Additional indicators are as follows:

DISPLAY

This is a seven segment character display that gives numerical

 

response to service personnel during programming and operation.

LEFT LIMIT

Indicates that the LEFT limit switch is activated.

RIGHT LIMIT

Indicates that the RIGHT limit switch is activated.

MTR LEFT

Indicates the gate is moving to the left.

MTR RIGHT

Indicates the gate is moving to the right.

RECV

Indicates data is being received from the other unit in a Master/

 

Slave system.

XMIT

Indicates data is being sent to the other unit in a Master/Slave

 

system.

OFF HOOK

Indicates the gate operator is off hook and using the phone line.

OBSTRUCTION

Indicates the peak or average motor current threshold was reached

 

and the motor was stopped. See Fault List.

INTERRUPT BAR

Indicates Interrupt Bar (Edge Sensor) switch was activated

(EDGE SENSOR)

and the motor was stopped.

OPEN MTR

Indicates the motor is engaged, but is not drawing any current. The

 

thermal overload switch on the motor may need to be reset. See

 

Fault List.

STUCK LIMIT

Indicates that a limit switch is stuck closed.

MAX RUN TIME

Indicates the motor ran for 75 seconds without reaching a limit switch

 

and was stopped. Usually requires mechanical service. See Fault

 

List.

LINE

Indicates an incoming telephone call ring detect and whether the

 

phone line is available when the gate operator wants to initiate a call.

MAG LOCK

Indicates the MagLock is engaged.

OBSTRUCTION

Indicates the Obstruction Alarm has sounded after two

ALARM

consecutive gate obstruction faults.

33 of 42

Doc 01-20099

Rev F