Install the Protector System®
1 Install the Safety Reversing Sensors
OPTION C FLOOR INSTALLATION
Use an extension bracket (not provided) or wood black to raise the sensor bracket if needed.
1.1C Carefully measure the position of both | 1.2C Attach the sensor brackets to the floor | 1.3C Slide the carriage bolt (H17) | 1.4C Insert the bolt through the hole in the sensor |
sensor brackets so they will be the same | using concrete anchors (not | into the slot on each sensor. | bracket and attach with the wing nut (H18). The |
distance from the wall and unobstructed. | provided). |
| lenses on both sensors should point toward |
|
| each other. Make sure the lens is not obstructed | |
|
|
| |
| (not provided) |
| by the sensor bracket. |
|
|
|
DE NSI GARAGE L WA
H17
H18
2 Wire the Safety Reversing Sensors
already has wires installed for the safety reversing sensors, proceed to page 26.
HARDWARE
OPTION A INSTALLATION WITHOUT PRE-WIRING
2.1A Run the wire from both sensors to the | 2.2A Strip 7/16 inch (11 mm) of | 2.3A Insert the white wires into the white terminal on |
garage door opener. Attach the wire to | insulation from each set of | the garage door opener. Insert the white/black |
the wall and ceiling with the staples. | wires. Separate the wires. Twist | wires into the grey terminal on the garage door |
| the white wires together. Twist | opener. To insert or remove the wires from the |
Staple | the white/black wires together. | terminal, push in the tab with a screwdriver tip. |
|
|
Insulated Staple
RED | WH TE | WH ET | GREY |
7/16"
(11 mm)