Install the Protector System®

OPTION B PRE-WIRED INSTALLATION

2.1B Cut the end of the safety

 

2.2B Separate the safety reversing sensor wires and strip 7/16 inch (11 mm) of

reversing sensor wire, making

 

insulation from each end. Choose two of the pre-installed wires and strip 7/16

sure there is enough wire to

 

inch (11 mm) of insulation from each end. Make sure that you choose the

reach the pre-installed wires

 

same color pre-installed wires for each sensor.

from the wall.

 

 

 

 

 

 

Safety reversing sensor wires

 

 

 

 

7/16"

Pre-installed

 

 

 

wires

 

 

 

(11 mm)

7/16"

 

 

 

 

 

 

 

 

(11 mm)

 

 

 

 

 

2.3B Connect the pre-installed wires to the sensor wires with wire nuts making sure the colors correspond for each sensor. For example, the white wire would connect to the yellow wire and the white/black wire would connect to the purple wire.

 

Not Provided

 

 

Yellow

 

White

(for example)

 

 

 

Pre-installed

 

 

wires

 

White/Black

Purple

 

 

(for example)

Safety reversing sensor wires

2.4B At the garage door opener, strip 7/16 inch (11 mm) of insulation from each end of the wires previously chosen for the

2.5B Insert the wires connected to the white safety sensor wires to the

safety reversing sensors. Twist the like-colored wires together.

white terminal on the garage door opener. Insert the wires that are

 

connected to the white/black safety sensor wires to the grey

 

terminal on the garage door opener.

 

Yellow

Purple

Yellow

(for example)

(for example)

Purple

 

 

 

DER WH TE WH TE

GREY

7/16"

 

To insert or remove

(11 mm)

 

 

the wires from the

 

 

 

 

terminal, push in the

 

 

tab with a screwdriver tip.

26