Instruction Manual

Plasma Display Electric Pop-Up Lift

 

 

TROUBLESHOOTING

If the lift is installed according to these instructions, it should operate trouble-free indefinitely. If you do encounter a problem, and it isn’t covered by the troubleshooting suggestions below, call the Technical Services Department at Chief Manufacturing:

1-800-582-6480

952-894-6280

 

 

Possible

 

 

Symptom(s)

 

Causes

Suggested Action

No Movement and No

 

No Power

1. Check power to unit (supply, cord, activation

Sound

 

 

control, and connections).

 

 

 

No power: Provide power, repair cord, tighten

 

 

 

 

connections or repair activation control.

 

 

 

Power:

Check fuse on circuit board. If fuse is OK,

 

 

 

 

proceed to next step.

 

 

Faulty Circuit Board

2. Check circuit board as follows:

 

 

 

Make three jumper wires with ends stripped.

 

 

 

Install one jumper wire on terminal 11.

 

 

 

Install one jumper wire on terminal 12.

 

 

 

Install one jumper wire on terminal 13.

 

 

 

Momentarily touch jumper wire from terminal 11 to

 

 

 

terminal 13. Unit should extend.

 

 

 

Momentarily touch jumper wire from terminal 12 to

 

 

 

terminal 13. Unit should retract.

 

 

 

Activates

 

 

 

 

In both

 

 

 

 

Directions: Circuit board OK, faulty activation

 

 

 

 

interface. Check remote switch, circuit, or

 

 

 

Unit

batteries in remote control.

 

 

 

 

 

 

 

Fails

 

 

 

 

Both/Either

 

 

 

Direction: Call Chief Manufacturing.

Unit Operates Noisily

 

Track Misalignment

1. Check for noise and/or metal shavings in track

(Squeeling or grinding)

 

 

Noise or

 

 

 

 

Shavings: Check and adjust track and/or shelf as

 

 

 

No Track

necessary.

 

 

 

 

 

 

 

Noise:

Possible brake problem, call Chief

 

 

 

 

Manufacturing

19

Page 20
Image 20
Chief Manufacturing 8805-000009 manual Troubleshooting, Possible Symptoms Causes Suggested Action