Chief Manufacturing 8805-000009 Volt Out Supply, Two Dry Contact Closures, Low Voltage Sensing

Models: 8805-000009

1 22
Download 22 pages 35.87 Kb
Page 18
Image 18

Instruction Manual

Plasma Display Electric Pop-Up Lift

 

 

12 Volt Out Supply

This internal power supply can be used to power external devices &/or to initiate specific functions (see Pushbutton operation and Figure 25).

1.Connect one lead to 12 VOLT GROUND (terminal #9).

2.Connect one lead to 12 VOLTS OUT (terminal #10).

24 Volt Out Supply

This internal power supply can be used to power external devices & remote controllers (see Figure 26).

1.Connect one lead to 24 VOLT COMMON (terminal #2).

2.Connect one lead to 24 VOLTS OUT (terminal #1).

Two Dry Contact Closures

NOTE: Dry contacts are rated for 1 Amp @ 24 volts.

These contacts can be used to complete circuits to external devices (see Figure 27 and Figure 28).

1.Connect one lead to terminal #17 (extend limit common).

2.Connect one lead to terminal #16 (closes when unit reaches full extension).

3.Connect one lead to terminal #19 (retract limit common).

4.Connect one lead to terminal #18 (closes when unit is fully retracted).

Low Voltage Sensing

1. Connect positive lead (5 - 30 volts AC/DC) to terminal #7 and ground of switching device to terminal #8 (see Figure 29). Unit extends when voltage is sensed, retracts when voltage ceases.

Example using internal 12 volt DC supply (Figure 30): 1 2 3 4 5 6 7 8

Figure 30. 12 Volt DC Supply

Figure 25. 12 Volts

Figure 24. 26 Volts

Figure 27. Extend Dry Contacts

Figure 28. Retract Dry Contacts

Figure 29. Low Voltage Sensing

17

Page 18
Image 18
Chief Manufacturing 8805-000009 manual Volt Out Supply, Two Dry Contact Closures, Low Voltage Sensing