Instruction Manual | Plasma Display Electric |
|
|
12 Volt Out Supply
This internal power supply can be used to power external devices &/or to initiate specific functions (see Pushbutton operation and Figure 25).
1.Connect one lead to 12 VOLT GROUND (terminal #9).
2.Connect one lead to 12 VOLTS OUT (terminal #10).
24 Volt Out Supply
This internal power supply can be used to power external devices & remote controllers (see Figure 26).
1.Connect one lead to 24 VOLT COMMON (terminal #2).
2.Connect one lead to 24 VOLTS OUT (terminal #1).
Two Dry Contact Closures
NOTE: Dry contacts are rated for 1 Amp @ 24 volts.
These contacts can be used to complete circuits to external devices (see Figure 27 and Figure 28).
1.Connect one lead to terminal #17 (extend limit common).
2.Connect one lead to terminal #16 (closes when unit reaches full extension).
3.Connect one lead to terminal #19 (retract limit common).
4.Connect one lead to terminal #18 (closes when unit is fully retracted).
Low Voltage Sensing
1. Connect positive lead (5 - 30 volts AC/DC) to terminal #7 and ground of switching device to terminal #8 (see Figure 29). Unit extends when voltage is sensed, retracts when voltage ceases.
Example using internal 12 volt DC supply (Figure 30): 1 2 3 4 5 6 7 8
Figure 30. 12 Volt DC Supply
Figure 25. 12 Volts
Figure 24. 26 Volts
Figure 27. Extend Dry Contacts
Figure 28. Retract Dry Contacts
Figure 29. Low Voltage Sensing
17