Instruction Manual

Plasma Display Electric Pop-Up Lift

 

 

Remote (RC-10)

RC-10 Controller

Circuit Board Box Assembly

RC-10 Remote

Figure 21. Contacts Connection

Wire for remote (RC-10) operation as follows (see Figure 21):

1.Install a jumper wire between terminals #6 and terminal #2 (see Figure 22).

2.Connect the white wire of the RC-10 controller unit to terminal #1 (see Figure 23).

3.Connect the red wire of the RC-10 controller unit to terminal #2.

4.Connect the black wire of the RC-10 controller unit to terminal #5.

5.Connect the power source to the lift.

NOTE: If the unit does not activate, check to make sure the 9 volt battery is working and make sure the dip switches in the send- ing unit match the dip switch settings in the controller unit (see Figure 24).

Figure 22. Contacts Connection

Red lead

Black lead

Figure 23. Contacts Connection

Figure 24. Dip Switches

15

Page 16
Image 16
Chief Manufacturing 8805-000009 manual Remote RC-10, Red lead Black lead