Chapter 2 Mounting Instructions
Mounting the Access Point
C i s c o C o n f i d e n t i a l - D r a ft 1
Grounding the Access Point
Warning This equipment must be externally grounded using a
Warning Installation of the equipment must comply with local and national electrical codes. Statement 1074
In all outdoor installations and when powering the access point with AC power, you must follow these instructions to properly ground the case:
Step 1 If using insulated
Step 2 Use the appropriate crimping tool to crimp the bare
Step 3 Connect the grounding lug to the access point grounding screw hole using the supplied Phillips head screw
Step 4 If necessary, strip the other end of the ground wire and connect to a reliable earth ground, such as a grounding rod or an appropriate grounding point on a metal streetlight pole that is grounded (see Figure
Streetlight Pole Installations
The access point can be installed where power is available, without the need for a wired LAN connection. The access point uses intelligent wireless routing that is based on the Adaptive Wireless Path Protocol (AWPP). AWPP enables a remote access point to dynamically optimize the best route to the wired LAN network using another access point.
The LAP1510 model uses the
The access point can be installed on a streetlight pole and powered from a streetlight outdoor light control using the optional streetlight power tap adapter.
Caution The access point can be powered by a light pole
When powering the access point with AC power other than the streetlight power tap adapter, you must ensure that the following conditions are observed:
1.AC power can be conveniently removed from the unit. The power should not be removed by disconnecting the AC power connector on the unit.
Cisco Aironet 1500 Series Outdoor Mesh Access Point Hardware Installation Guide
|
|
| |
|
|