12-13
Catalyst 3560 Switch Software Configuration Guide
OL-8553-06
Chapter 12 Configuring Auto Smartports Macros
Configuring Static Smartports Macros
You can only delete a global macro-applied configuration on a switch by entering the no version of each
command in the macro. You can delete a macro-applied configuration on a port by entering the default
interface interface-id interface configuration command.
Step 4 macro global {apply | trace}
macro-name [parameter {value}]
[parameter {value}] [parameter
{value}]
Apply each individual command defined in the macro to the switch by
entering macro global apply macro-name. Specify macro global trace
macro-name to apply and to debug a macro to find any syntax or
configuration errors.
Append the macro with the required values by using the parameter
value keywords. Keywords that begin with $ require a unique parameter
value.
You can use the macro global apply macro-name ? command to display
a list of any required values for the macro. If you apply a macro without
entering the keyword values, the commands are invalid and are not
applied.
(Optional) Specify unique parameter values that are specific to the
switch. You can enter up to three keyword-value pairs. Parameter
keyword matching is case sensitive. The corresponding value replaces
all matching occurrences of the keyword.
Step 5 interface interface-id (Optional) Enter interface configuration mode, and specify the interface
on which to apply the macro.
Step 6 default interface interface-id (Optional) Clear all configuration from the specified interface.
Step 7 macro {apply | trace} macro-name
[parameter {value}] [parameter
{value}] [parameter {value}]
Apply each individual command defined in the macro to the port by
entering macro global apply macro-name. Specify macro global trace
macro-name to apply and to debug a macro to find any syntax or
configuration errors.
Append the macro with the required values by using the parameter
value keywords. Keywords that begin with $ require a unique parameter
value.
You can use the macro global apply macro-name ? command to display
a list of any required values for the macro. If you apply a macro without
entering the keyword values, the commands are invalid and are not
applied.
(Optional) Specify unique parameter values that are specific to the
switch. You can enter up to three keyword-value pairs. Parameter
keyword matching is case sensitive. The corresponding value replaces
all matching occurrences of the keyword.
Step 8 end Return to privileged EXEC mode.
Step 9 show running-config interface
interface-id
Verify that the macro is applied to an interface.
Step 10 copy running-config startup-config (Optional) Save your entries in the configuration file.
Command Purpose