4-10
Catalyst 3560 Switch Software Configuration Guide
OL-8553-06
Chapter 4 Configuring Cisco EnergyWise
Managing Single Entities
Step 3 energywise domain domain-name secret [0 | 7]
password [protocol udp port udp-port-number
[interface interface-id | ip ip-address]]
Enable EnergyWise on the entity, assign the entity to a domain
with the specified domain-name, and set the password for secure
communication among the entities in the domain.
(Optional) 0—Use an unencrypted password. This is the
default.
(Optional) 7—Use a hidden password.
If you do not enter 0 or 7, the entity uses the default value of
0.
(Optional) port udp-port-number—Specify the UDP port
that sends and receives queries.
The range is from 1 to 65000.
The default is 43440.
(Optional) interface interface-id—Specify the port that
sends EnergyWise messages.
(Optional) ip ip-address—Specify the IP address of the port
that sends EnergyWise messages.
For the domain-name and password,
You can enter alphanumeric characters and symbols such as
#, (, %, !, or &.
Do not use an asterisk (*) or a blank space between the
characters and symbols.
By default, no domain and password are assigned.
Step 4 interface interface-id Specify the port or a range of ports to be configured, and enter
interface configuration mode.
Step 5 energywise level 10 recurrence importance
importance at minute hour day_of_month month
day_of_week
(Optional) Schedule the power-on recurrence.
importance importance—Set the importance of the port in
the domain. The range is from 1 to 100. The default is 1.
minute—The range is from 0 to 59. Use * for the wildcard.
hour—The range is from 0 to 23. Use * for the wildcard.
day_of_month—The range is from 1 to 31. Use * for the
wildcard.
month—The range is from 1 (January) to 12 (December). Use
* for the wildcard.
day_of_week—The range is from 0 (Sunday) to 6 (Saturday).
Use * for the wildcard.
Note The specified time is the local time based on the
PoE-entity time zone.
Command Purpose