Appendix A Technical Specifications

Router Specifications

Table A-1

Cisco 819 ISR Specifications (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hardened Design

Non-Hardened Design

 

 

 

 

 

 

 

 

Specification

Specifications

 

 

 

 

 

 

 

 

 

 

Hardened Design Specifications

 

 

 

(Cisco 819HG and Cisco

(Cisco 819G and Cisco

 

 

 

 

 

 

Description

 

819HG-4G ISRs)

819G-4G ISRs)

(C819HGW and C819HWD ISRs)

 

 

 

 

 

 

 

Maximum Power

11 W

 

20 W

 

Consumption

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Environmental Operating Ranges

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Temperature and

–13 to 140°F

32 to 104°F

–13 to 140°F

 

Altitude

 

(–25 to 60°C)

(0 to 40°C)

(–25 to 60°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

Derate max operating temperature 1.5°C per 1000 feet above 5000 ft

 

 

 

 

 

 

 

 

 

 

 

 

 

10,000 ft maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Humidity

 

Maximum 95%

Maximum 85%

Maximum 95% non-condensing

 

 

 

non-condensing RH

non-condensing RH

RH

 

 

 

 

 

 

 

 

 

 

Environmental Tests

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ingress Protection Rating

IP 41 per IEC 60529 for

IP 20 per IEC 60529

IP 41 per IEC 60529 for Vertical

 

 

 

Vertical Falling Water,

 

Falling Water, Pollution Degree 3

 

 

 

Pollution Degree 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Humidity

 

Non-condensing Relative Humidity: 5% to 95%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pollution

 

Pollution 3 for Dust

 

 

 

 

 

 

 

 

 

 

 

Military Standard

MIL-STD-810G Method 514.6: Procedure 1 Category 4, Secured Cargo - Common Carrier

 

 

 

 

 

 

 

 

MIL-STD-810G Method 514.6: Procedure 1 Category 20, Ground Vehicles

 

 

 

 

 

 

 

 

MIL-STD-810G Method 516.6. Procedure 1, Functional Shock

 

 

 

 

 

 

 

 

MIL-STD-810G Method 516.6. Procedure 5, Crash Hazard

 

 

 

 

 

 

 

 

MIL-STD-810G Method 516.6. Procedure 6, Bench Handling

 

 

 

 

 

 

 

 

 

Vibration and Shock

EN61373 Functional Random Vibe - Category 1, Class B

 

 

 

 

 

 

(Railway Vehicles)

 

 

 

 

 

 

 

 

EN61373 Simulated Non-op Long-life Vibe - Category 1, Class B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN61373 Non-op Shock, Class B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heavy-Duty Vehicle

SAE J1455 Operating Random Vibe, Cab Mounted Truck

 

 

 

 

 

 

Applications

 

 

 

 

 

 

 

 

 

 

SAE J1455 Operating Sinusoidal Vibe, Category 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAE J1455 Non-operating Sinusoidal Vibe, Category 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAE J1455 Handling Drop Test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Certifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Safety

 

UL 60950-1, 2nd edition; CAN/CSA C22.2 No. 60950-1,

UL 60950-1, 2nd edition;

 

Certifications

 

2nd edition, EN 60950-1, 2nd edition; CB to IEC

CAN/CSA C22.2 No. 60950-1, 2nd

 

 

 

60950-1, 2nd edition with all group differences and

edition, EN 60950-1, 2nd edition;

 

 

 

national deviations

 

CB to IEC 60950-1, 2nd edition

 

 

 

 

 

with all group differences and

 

 

 

 

 

national deviations; S/NZS

 

 

 

 

 

60950-1, first edition

 

 

 

 

 

(Australia/New Zealand)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco 819 Integrated Services Router Hardware Installation Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-23125-02

 

 

 

 

 

A-2

 

 

 

 

 

 

 

 

Page 78
Image 78
Cisco Systems C819G4GAK9, C819GUK9, C819HK9 manual Maximum Power 11 W 20 W Consumption