Dual Phone System Integration

Changing Cisco Unity Administrator Settings

The access code is the same number that subscribers on the circuit-switched phone system dial to reach someone on the Cisco CallManager system.

Step 3 Adjust other settings as applicable. For more information about the other settings on the Switch page, refer to the Cisco Unity Administrator Help.

Step 4 Click the Save icon, then click OK in the Warning dialog box.

To specify switch settings for Cisco CallManager

Step 1

Go to System > Switch > IP Switch.

Step 2

In the Set Active Switch Type section, enter values as shown in the following table:

 

Table 23

Switch Settings

 

 

 

 

 

Switch Parameter

Required Setting

 

 

 

 

 

Manufacturer

 

Cisco

 

 

 

 

 

Model

 

CallManager

 

 

 

 

Switch PBX software version

3.01 or later

 

 

 

 

 

Integration

 

TAPI

 

 

 

Step 3

Click Set As Active, then click OK in the Warning dialog box.

Step 4

In the Access Code field, enter the trunk access code that Cisco Unity must dial to transfer calls to the

 

circuit-switched phone system from Cisco CallManager.

The access code is the same number that subscribers on Cisco CallManager dial to reach someone on the circuit-switched phone system.

Step 5 Click the Save icon, then click OK in the Warning dialog box.

To Modify Voice Port Settings

Step 1 In the Cisco Unity Administrator, go to the System > Ports page.

Step 2 In the Port Assignments section, indicate the range of ports to be assigned to the circuit-switched phone system. The port range for the circuit-switched phone system begins with 1 and extends to no more than the number of ports that are on the installed voice cards. Do not assign more ports to the circuit-switched phone system than the number of ports on the voice cards.

Caution If you assign fewer voice ports to the circuit-switched phone system than are available on the installed voice cards, you must edit the registry for this port range to take effect. Otherwise, all available voice ports on the voice cards are used in the integration regardless of the Port Assignments settings. For information on editing the registry for the port range, see the appendix “Assigning Dialogic Ports for a Dual Phone System Integration.”

Step 3 In the Port Assignments section, indicate the range of ports to be assigned to Cisco CallManager. The port range must begin with the next port after the last port for the circuit-switched phone system. The range for Cisco CallManager must end with the port number of the last port displayed on the Ports page,

Avaya Definity Gx/PBXLink Integration Guide for Cisco Unity 3.1

28

OL-1846-06

 

 

Page 28
Image 28
Cisco Systems Cisco Unity 3.1 manual To specify switch settings for Cisco CallManager, Go to System Switch IP Switch