7-6
Cisco IE 3010 Switch Software Configuration Guide
OL-23145-01
Chapter 7 Configuring the Switch Alarms
Configuring IE 3010 Switch Alarms
ALARM CONTACT 3
Status: not asserted
Description: flood sensor
Severity: critical
Trigger: closed
ALARM CONTACT 4
Status: not asserted
Description:
Severity: critical
Trigger: closed
Configuring IE 3010 Switch Alarms
Default Switch Alarm Configuration, page 7-6
Configuring the Power Supply Alarms, page 7-6
Configuring the Switch Temperature Alarms, page 7-7
Configuring the FCS Bit Error Rate Alarm, page 7-10
Configuring Alarm Profiles, page 7-11
Enabling SNMP Traps, page 7-13

Default Switch Alarm Configuration

Configuring the Power Supply Alarms

The presence of power supplies is dynamically detected. Use the show env power command in
privileged EXEC or user EXEC mode to display power information for the switch.
Use the alarm facility power-supply global configuration command to associate the power supply
alarm to the relay. You can also configure all alarms and traps associated with the power supply alarm
to be sent to syslog and the SNMP server.
Tab l e 7-3 Default Switch Alarm Configuration
Alarm Default Setting
Global Power supply alarm Enabled in switch single power mode. No alarm.
In dual-power supply mode, the default alarm notification is a system
message to the console.
Primary temperature alarm Enabled for switch temperature range of 203oF (95oC) maximum to –4°F
(–20oC) minimum.
The primary switch temperature alarm is associated with the major relay.
Secondary temperature alarm Disabled.
Port Link fault alarm Disabled on all interfaces.
Port not forwarding alarm Disabled on all interfaces.
Port not operating alarm Enabled on all interfaces.
FCS bit error rate alarm Disabled on all interfaces.