7-8
Cisco IE 3010 Switch Software Configuration Guide
OL-23145-01
Chapter 7 Configuring the Switch Alarms
Configuring IE 3010 Switch Alarms
Beginning in privileged EXEC mode, follow these steps to set the high temperature threshold:
Use the no alarm facility temperature primary high threshold global configuration command to delete
the temperature monitoring alarm configuration and return to the default setting.
This example shows how to delete the primary temperature monitoring alarm configuration and return
to the default setting.
Switch(config) # no alarm facility temperature primary high 45
Setting a Secondary Temperature Threshold for the Switch
You can use the alarm facility temperature secondary global configuration command to set the low
and high temperature thresholds for the secondary temperature monitoring alarm.
Beginning in privileged EXEC mode, follow these steps to set the low temperature threshold:
Use the no alarm facility temperature secondary threshold global configuration comm and to disable
the secondary temperature threshold alarm.
This example disables the secondary temperature threshold alarm.
Switch(config) # no alarm facility temperature secondary 45
Command Purpose
Step 1 configure terminal Enter global configuration mode.
Step 2 alarm facility temperature primary
high threshold
Set the primary high temperature threshold value. Set the threshold from
–238°F (–150°C) to 572°F (300°C).
Step 3 alarm facility temperature primary
low threshold
Set the primary low temperature threshold value. Set the threshold from
–328°F (–200°C) to 482°F (250°C).
Step 4 end Return to privileged EXEC mode.
Step 5 show alarm settings Verify the configuration.
Step 6 copy running-config startup-config (Optional) Save your entries in the configuration file.
Command Purpose
Step 1 configure terminal Enter global configuration mode.
Step 2 alarm facility temperature
secondary high threshold
Set the secondary high temperature threshold value. Set the threshold from
–238°F (–150°C) to 572°F (300°C).
Step 3 alarm facility temperature
secondary low threshold
Set the secondary low temperature threshold value. Set the threshold from
–328°F (–200°C) to 482°F (250°C).
Step 4 end Return to privileged EXEC mode.
Step 5 show alarm settings Verify the configuration.
Step 6 copy running-config startup-config (Optional) Save your entries in the configuration file.