Cisco Systems WSC385024TS, C3850NM210G manual Fan Module Installation, Installing a Fan Module

Models: C3850NM41G C3850NM210G WSC385024TS

1 114
Download 114 pages 36.02 Kb
Page 84
Image 84
Fan Module Installation

Chapter 5 Installing the Fan

Fan Module Installation

Figure 5-1

Fan Module

1 2

43

344200

1

Fan LED

3

Retainer clip

 

 

 

 

2

Exhaust vent

4

Extraction handles

 

 

 

 

Fan Module Installation

Installation Guidelines

Observe these guidelines when removing or installing a fan module:

Do not force the fan module into the slot. This can damage the pins on the switch if they are not aligned with the module.

A fan module that is only partially connected can disrupt the system operation.

The switch supports hot swapping of the fan module. You can remove and replace the module without interrupting normal switch operation.

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

Statement 1030

Installing a Fan Module

Step 1 Pinch the fan module release handle, and slide the module out.

Caution You should replace the fan module within 5 minutes to avoid overheating the switch.

Catalyst 3850 Switch Hardware Installation Guide

5-2

OL-26779-02

 

 