CBM1000 Service Manual

2.Removing the Platen SA

(1)While pushing the pressure arm downwardly, turn the platen bushing by 90 degrees in either direction. (Then, the flat surfaces of the left side platen bushing are set in vertical.)

(2)Lift the left side platen SA to disengage it from the U-shaped groove on the main chassis.

(3)Pull the platen SA to the left to remove it from the main chassis.

3.Removing the Center Frame SA

(1)Remove the four screws M3 × 6 (BT).

(2)Remove the center frame SA from the main chassis by lifting it upward.

Note on reassembling:

Pass the connector A and B through the holes A and B on the main chassis, re- spectively.

Platen Bushing

Platen SA

Flat Surface

Main Chassis

Pressure Arm

Center Frame SA

M3×6 (BT)

Main Chassis