ESC S n

[Function]

Setting serial interface communication speed

[Code]

<1B>H<53>H<n>

[Range]

{0 =< n =< 6(Hex)}

 

{30 =< n =< 36(Hex)}

 

 

 

 

n (Hex)

Speed (bps)

 

0, 30

1200

 

1, 31

2400

 

2, 32

4800

 

3, 33

9600

 

4, 34

19200

 

5, 35

57600

 

6, 36

115200

[Outline]

Sets the communication speed for the serial interface.

 

The command is valid only when the printer is connected through a serial cable. It is

 

not valid when using IrDA interface. The last setting is valid even after the printer is

 

switched OFF.

[Default]

The default value is 3 [9600 BPS]

ESC T

[Function]

Printing Diagnostic information

[Code]

<1B>H<54>H

 

[Outline]

Prints current printer attributes and diagnostics.

[See Also]

ESC .

 

[Print Results]

CITIZEN Mobile Printer

 

/////////////////////////////////////////////

 

Model CMP-10 Ver x.xxXX

 

Intensity:

100%

 

Timeout:

10 min

 

Temperature:

27°C

 

Battery:

7.5V [**...]

 

Mode:

RS232

 

Speed:

9600 bps

 

Switches:

0 0 0 0 0 0 0 0

— 28 —

Page 30
Image 30
Citizen manual ESC S n, Esc T, Hex Speed bps, Model CMP-10 Ver