ESC c5 n

[Function]

Enabling/Disabling Panel Switches

[Code]

<1B>H<63>H<35>H<n>

[Range]

{0 =< n =< FF(Hex)}

[Outline]

Selecting the LF switch valid/invalid.

 

• “n” is valid only in the lowest bit (n0).

 

 

 

 

n (Hex)

Condition

 

0

LFSW valid.

 

1

LFSW invalid.

[Caution]

• When the panel switch is disabled with this command, the LF switch is disabled.

 

Therefore, the paper cannot be fed by operating the LF switch.

 

• When LF switch is set to Invalid, it cannot be cleared by the Initialize command

 

(ESC @) but is cleared by turning power off.

[Default]

The initial value of n is “0”.

[Sample Program]

 

 

PRINT #1, CHR$ (&H1B) + “c5” + CHR$ (0); ……When enabling the LF switch

PRINT #1, CHR$ (&H1B) + “c5” + CHR$ (1); ……When disabling the LF switch