iDP-3210 User’s Manual

6.1.3 I/O SIGNALS

(1) Input Signals to the Printer

DATA

: 8-bit parallel signal (positive logic)

STB

: Strobe signal to read 8-bit data (negative logic)

RESET

: Signal to reset the entire printer (negative logic) 1m sec or more

(2) Output Signals from Printer

ACK

: An 8 bit data request signal. Pulse signal output at the end of

 

 

the BUSY signal. (negative logic)

BUSY

: The signal to indicate BUSY state of the printer. Input new data for "LOW".

 

 

(positive logic)

FAULT

: The signal which is made "LOW" when the printer is in alarm state. All the

 

 

control circuits inside the printer are stopped at this time.(negative logic)

PE

: The signal which is output when paper runs out or goes scarce. (positive logic)

Drawer Switch Output

:With the switch open, this signal goes "HIGH". When shorting, this goes "LOW".

(3)Power supply • +5 V DC • GND

:This is 5V pulled up by a 3.3k Ohm resistor.

:This is the common ground for the circuit.

CITIZEN