iDP-3210 User’s Manual

6.2 Serial Interface

6.2.1Specifications

(1)Data transfer system: Asynchronous

(2)Baud rates

150, 300, 600, 1200, 2400, 4800, 9600, 19200 bps (Selectable by user)

(3)

Configuration of one word

 

 

 

Start bit

:

1 bit

 

 

 

Data bit

:

7 bits or 8 bits (Selectable by user))

 

Parity bit

:

Add/even or no parity

(Selectable by user)

 

Stop bit

:

1 bit or more

 

 

(4)

Signal polarity

 

 

 

 

 

RS-232C

 

 

 

 

 

Mark

 

= Logic " 1" (-3V

-

-12V)

 

Space

 

= Logic " 0" (+3V

-

+12V)

(5)Receive data (RD signal) RS-232C

Mark

= 1

Space

= 0

(6)Data receiving control (DTR signal) RS-232C

Mark

:

Data transfer not available

Space

:

Data transfer available

(7) Data transmission control (TD signal)

DC1 code (11H)

X-ON

: Data reception available

DC3 code (13H)

X-OFF

: Data reception not available

CITIZEN

37

 

Page 37
Image 37