ACONN - Audible Connect / Disconnect Indication

This command selects/reports the status of the audible connect/disconnect indication.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group and Channels

 

Group

Group

1

17 (R)

 

Value

Unsigned Integer

2

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

BINARY FORM DETAILS

 

 

 

 

COMMAND ID:

96

 

 

 

NUMBER OF ARGUMENTS: 1

 

 

 

ARGUMENT FORM:

<Channel><Group><Value>

 

TEXT FORM DETAILS

COMMAND FORM:DEVICE ACONN <Channel> [Value]

AD - Auto Disconnect Enable/ Disable

This command selects/reports the setting of auto disconnect.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group and Channels

 

Group

Group

1

17 (R)

 

Value

Unsigned Integer

2

0

= Off

 

 

 

 

1

= Loop Drop

 

 

 

 

2

= Call Progress

 

 

 

 

3

= Loop Drop + Call Progress

 

 

 

 

(Null to query in text)

 

BINARY FORM DETAILS

 

 

 

 

COMMAND ID:

29

 

 

 

NUMBER OF ARGUMENTS: 1

 

 

 

ARGUMENT FORM:

<Channel><Group><Value>

 

TEXT FORM DETAILS

 

 

 

 

COMMAND FORM:

DEVICE AD <Channel> [Value]

 

Appendix— Serial Commands

 

85

 

AEC - Acoustic Echo Canceller enable/ disable

This command selects/reports the setting of Acoustic Echo Canceller.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group And Channels

 

Group

Group

1

3

(M)

 

Value

Unsigned Integer

2

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle(Null to query in text)

 

BINARY FORM DETAILS

 

 

 

 

COMMAND ID:

27

 

 

 

NUMBER OF ARGUMENTS: 1

 

 

 

ARGUMENT FORM:

<Channel><Group><Value>

 

TEXT FORM DETAILS

COMMAND FORM:DEVICE AEC <Channel> [Value]

AECREF - Acoustic Echo Cancellation Reference

This command enables/disables or reports the current status of the AEC reference.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Value

Unsigned Integer

4

1 - 3

 

 

 

 

(Null to query in text)

 

BINARY FORM DETAILS

 

 

 

COMMAND ID:

68

 

 

NUMBER OF ARGUMENTS: 1

 

 

ARGUMENT FORM:

<Value>

 

 

TEXT FORM DETAILS

 

 

 

COMMAND FORM:

DEVICE AECREF [Value]

 

AGC - Automatic Gain Control

This command selects/reports the setting of automatic gain control.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group And Channels

 

Group

Group

1

3

(M)

 

Value

Unsigned Integer

2

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

BINARY FORM DETAILS

 

 

 

 

COMMAND ID:

1

 

 

 

NUMBER OF ARGUMENTS: 1

 

 

 

ARGUMENT FORM:

<Channel><Group><Value>

 

TEXT FORM DETAILS

 

 

 

 

COMMAND FORM:

DEVICE AGC <Channel> <Group> [Value]

 

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760