26

Appendix C ~ Serial Commands

FLOW

This command selects or reports whether hardware flow control is enable or disabled

for the GT1524. Hardware flow control is implemented using RTS and CTS.

Command form: FLOW <X>

Explanation

Value

0

= Sets flow control to Off

 

1

= Sets flow control to On

Null = Returns the current mode

Return values

The command will return the updated condition (On=1, Off=0) of the GT1524 in

the same format as the command.

FPP

This command sets and reports the current passcode setting for the GT1524.

Command form: FPP <X>

Explanation

Value

1 = Up button

 

2

= Enter button

 

3

= ESC button

 

4

= Down button

 

5

= Meter button

Null = Return current passcode

Return values

The command returns the current or updated condition of the front panel passcode.

GAIN

This command changes or reports back the gain for a channel. The command

supports all inputs and outputs. Command form: GAIN<CH><X1><X2>[X3]

Explanation

Channel

1

= Mic/Line Input, Line Output

 

2

= Aux Input, Aux Output

 

3

= 4 Wire Input, 4 Wire Output

 

4

= Telco Input, Telco Output

Value 1

I = Selects Input, O = Selects Output

Value 2

-20 to 20 to set the level

 

Null to return the current level

Value 3

R = Indicates relative

 

A = Indicates absolute

 

Null will default to R (relative)

Return values

The command will return the updated level of the channel in the same format as the

command. The level returned is always absolute.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 31
Image 31
ClearOne comm GT1524 operation manual Flow, Fpp, Gain