Installation ~ LCD Programming

Ring Indication. An audible ring indicator, sent to the PA output, can be enabled or disabled under this menu.

Disabling the timeout will allow the GT1524 to remain in the same

position in the LCD menu until the LCD menu is manipulated again.

Unit ID Number

The Unit ID # allows you to view the read-only unit address set at the factory. This unique ID number identifies that particular unit and cannot be changed.

Meters

There are five main submenus under the meter menu tree: Inputs, Outputs, ERL/TERL, ERLE/TERLE, and Default Meter. The first four submenus are all handled in the same way.

Inputs, Outputs, ERL/TERL, and ERLE/TERLE

Referencing the LCD, press the Meter button, then scroll through the options (Inputs, Outputs, ERL/TERL and ERLE/TERLE) to specify which is to be metered by the front-panel LED meter. When the appropriate option is visible, press Enter to begin monitoring its status on the front panel LCD. All items under this menu can be scrolled through by pressing the ▲/▼ arrows.

Default Meter

The default meter parameter determines what is being displayed on the LED meter when the GT1524 times out.

Timeout

The GT1524 has a system mode called Timeout. This parameter can be adjusted through the RS-232 port only using the TOUT command. Timeout controls the delay time (in minutes) before the LCD panel will automatically switch back to the title screen and default meter. The range is 0–15 minutes. Default is 10 minutes; 0 disables this mode.