32

Appendix C ~ Serial Commands

TOUT

This command sets or reports the current inactivity timeout before returning to the menu screen used by the unit. Command form: TOUT <X>

Explanation

Value

0 = Disables inactivity timeout

 

1–15 = Sets the number of minutes specified

 

Null = Returns the current number of minutes

Return Values

The command will return the current timeout value. If the command changed the timeout, the updated timeout is returned.

UID

This command returns the unique ID number, the device type, and the device number of the GT1524. This command is read only. The unique ID number is preprogrammed at the factory and is unique to the unit. Command form: UID

Return Values

UID returns the device type and unique ID number. The unique ID is composed of an eight-digit hex number assigned at the factory to uniquely identify the unit.

Example

The following command requests the unit ID from device: UID

The following is returned out the serial port: UID A4EF906C

VER

This command returns the current version of software. This version is unique to a released version of software and is comprised of the DSP, the FPGA, and HC11 software. This command is read only. VER

Return Values

VER returns the version of software in the same format as the command. The Version is composed of a major version number followed by a period and a minor version number.

Example

The following command requests the software version: The following is returned out

the serial port: VER 2.0

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 37
Image 37
ClearOne comm GT1524 operation manual Tout, Uid, Ver