30

Appendix C ~ Serial Commands

PP

This command changes or reports back the state of the phantom power for a

microphone. Command form: PP <X>

Explanation

Value

0

= Sets the state to Off

 

1

= Sets the state to On

Null = Returns the current state

Return values

The command will return the updated condition (On=1, Off=0) of the phantom

power in the same format as the command.

RING

This command reports the presence of a Ring on the Telco port. (This is an indication

only.) Command form: RING

Return value

The Ring is sent if a valid ring has been sensed on the Telco line: RING

RINGEN

This command changes or reports back the state of the Ring Indication.

Command form: RINGEN <X>

Explanation

Value

0

= Sets the state to Off

 

1

= Sets the state to Ring 1

 

2

= Sets the state to Ring 2

 

3

= Sets the state to Ring 3

 

4

= Sets the state to Ring 4

Null = Returns the current state

Return values

The command will return the updated condition of the Ring Indication in the same

format as the command.

RXRD

This command controls or reports the Receive Reduction control of the unit.

Command form: RXRD <X>

Explanation

Values

0

= Sets Receive Reduction to Off

 

1

= Sets Receive Reduction to On

 

2

= Toggles the current state

Null = Reports back the current state

Return values

The command returns the updated connection state of the unit in the same format as

the command.