111

Technical Ser vices Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices ~ Appendix E: Serial Commands

LFP - Lock Front Panel

This command sets and reports front panel access for the unit. When the unit is
locked, access is not allowed to the unit until the unit is unlocked.
Command form: DEVICE
LFP
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
LFP Command form
Value 0 = Unlock Panel, 1 = Lock Panel, 2 = Toggle Value,
3 = Lock when timed out
Example:
#54 LFP 1
The XAP 800 unit 4 (
#54
), front panel (
LFP
) is locked (
1
).

LMO - Last Mic On Mode

This command selects/reports last Mic on mode for the specified gating group.
Command form: DEVICE
LMO
<Channel> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
LMO Command form
Channel See Groups and Channels, page 97
Value 0 = Last Mic Mode disabled
1–8 = Select Last Mic mode on specified channel
* = Last mic to stay on, Null to return the cur rent mode
Example:
#50 LMO A 0
On XAP 800 unit 0 (
#50
), the Last Mic Mode (
LMO
)
for gating group
A
is disabled (
0
).

LOCK - Preset and Macro Lock

This command selects/reports the state of the preset and macro lock. When on, the
lock prevents flagged presets and macros from being altered in any way.
Command form: DEVICE
LOCK
[Value][Password]
Argument details
Name Description
Device 0–7 or * to select all units
LOCK Command form
Value 0 = Off, 1 = On, 2 = Toggle
Password Only needs to be entered when changing the lock. For security,
this value is not returned.
Example:
#51 LOCK 1 “password”
On XAP 800 unit 1 (
#51
), any presets or
macros that have been flagged with the LOCKPRST command will be locked
(
LOCK
) and password protected (
1
) with the macro/preset
password
(LOCKPWD).