ClearOne comm XAP 800 108, Gate Gate Status, GHOLD- Gate Hold Time Adjust, Example

Models: XAP 800

1 151
Download 151 pages 52.56 Kb
Page 115
Image 115

108

Appendices ~ Appendix E: Serial Commands

GATE - Gate Status

This command reports the gate status of mics. This command is read only.

Command form: DEVICE GATE

Argument details

Name

Description

Device

0–7 or * to select all units

GATE

Command form

The command will return the gate status of mic inputs 1–8 in hexadecimal.

Example:

If

Hex # returned

 

 

Hexadecimal Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

 

 

Mic 8

Mic 7

Mic 6

Mic 5

Mic 4

Mic 3

Mic 2

Mic 1

Mics 1 and 2 are gated on

0 3

0

0

0

0

0

0

1

1

Mics 1 and 3 are gated on

0 5

0

0

0

0

0

1

0

1

Mics 1, 4, and 7 are gated on

4 9

0

1

0

0

1

0

0

1

Mics 3–6 and 8 are gated on

B C

1

0

1

1

1

1

0

0

 

 

 

First digit

 

 

Second digit

 

GHOLD- Gate Hold Time Adjust

This command selects/reports the setting of hold time.

Command form: DEVICE GHOLD <Channel> [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

 

GHOLD

Command form

 

Channel

See Groups and Channels, page 97

 

Value

0.10-8.00

S

 

Null to return the current hold time

 

Example: #50 GHOLD 1 .3 On XAP 800 unit 0 (#50), the hold time (GHOLD) for mic channel 1 is 300ms (.3).