Control ~ Remote Builder

To program the XAP IR Remote

1.Select an ID number for the remote from the Select Remote ID list.

2.Click Change Name to create a more descriptive name for the remote which is displayed in addition to the remote number (limit 20 characters).

3.Select IR Remote (default) from the Select Remote Type list.

4.In the Telephone Interface section, select the Device Type and ID of the unit (XAP 400 or XAP TH2) that you want the XAP IR remote to use when making and receiving calls. The default settings are ** which will select any telco device found on the network. If you have multiple telco devices in your network, you must specify which unit will be used to make and receive calls.

5.Select the button or LED you want to program from the Select Button/LED list. You can also select the button or LED by clicking directly on the picture of the remote. (Selectable buttons are colored white.)

6.Click the Active Command or Inactive Command button to set the command for operation when the button is active or inactive.

7.Select the Device Type, ID, and Command from their respective lists. When you select a command, a description of it appears in the Command Description box.

8.Select the command parameters from the argument lists. The parameters that are available depend on the command selected. When you select an argument, a description of it appears in the Argument Description box.

9.Click the Apply button to apply the command to the selected Active or Inactive command button. Or, click Clear to clear any programming.

ClearOne Control Panels

ClearOne Control Panels are convenient wall panels which provide control over the

XAP 800 audio conferencing system. There are two Control Panel models: Volume

and Select. You can connect up to six Control Panels in daisy chain fashion to each

RS-485 port. See Appendix C for more information. The Control Panel buttons are

programmed using the Remote Builder. You can open the Remote Builder using the

Remote Builder button on the Flow Screen or the Remote Builder button on the

G-Ware toolbar.

79

Up to five control panels and one IR remote can be connected to each of the RS-485 ports. In addition to selecting the ID number in the software, you will also need to use the DIP switches on the IR receiver to assign the Device ID. See the XAP IR Remote manual for more