Cleveland Range KGT-25 Safety Inspection Checklist, TILTING MODELS pg. 1 of, Safety Valve, Plug

Models: KGL-25-T KGT-25 KGL-25 KGT-25-T KCL-25-T

1 36
Download 36 pages 376 b
Page 23
Image 23
SAFETY INSPECTION CHECKLIST-
Safety valve has plug threaded into the discharge opening preventing any steam from escaping.
Safety valve’s tube diameter has been reduced.

SAFETY INSPECTION CHECKLIST-

TILTING MODELS (pg. 1 of 2)

Regular inspection and maintenance of units is essential to obtain trouble free and safe operation of equipment. Inspections must include testing of the pressure relief valve and checks of the operating system to insure that it has not been altered.

No safety features designed into the equipment should ever be tampered with. Tampering with or bypassing controls is a very dangerous practice and unfortunately we have seen several cases of this. Following is a short list of the most common and the most dangerous alterations performed on kettles.

SAFETY VALVE:

This illustrations show the correct configuration of a factory installed Safety Valves.

Any modifications are unacceptable.

Incorrect Installations

1

2

3 Safety valve is sticking, frozen shut or plugged. To test, refer to page 23, PRESSURE RELIEF VALVE PERIODIC TESTING PROCEDURE.

4 Safety valve is plumbed to a drain or water line creating back pressure and reducing flow.

1TILTING MODELS (pg. 1 of 2)

Plug

2 SAFETY VALVE:Incorrect Installations Tube diameter reduced

Plug2  Tube diameter reduced

Frozen,

3 stuck, or plugged

Plumbed to drain or water line

4

This illustrations show the correct configuration of a factory installed Safety Valves.

Any modifications are unacceptable.

20

Page 23
Image 23
Cleveland Range KGT-25 Safety Inspection Checklist, TILTING MODELS pg. 1 of, Safety Valve, Incorrect Installations, Plug