SAFETY INSPECTION CHECKLIST-
TILTING MODELS (pg. 2 of 2)
SAFETY THERMOSTAT: | Incorrect | |
Installations | ||
|
✔
Probe fully inserted in tube
Wiring is properly
connected
1 | 2 | 3 | Safety thermostat |
|
|
| 1 probe is not |
|
|
| completely |
|
|
| inserted into |
|
|
| tubing. |
|
|
| Safety thermostat |
|
|
| 2 probe is removed |
✘ | ✘ | ✘ | from tubing. |
Safety thermostat | |||
Probe | Probe | Thermostat | 3 electrical |
removed | removed | electrically | connection is |
partially | completely | bypassed | bypassed. |
Low Water Level Probe:
✔Probe properly attached
(A)
(B)
✘ | Probe bypassed by | ✘ |
| Probe bypassed by |
running (A) an |
| (B) grounding the | ||
| additional wire |
|
| connecting wire |
|
|
| ||
|
|
|
|
|
Operating Thermostat:
265º
260º - 270º
✔MAXIMUM KETTLE TEMPERATURE
If maximum temperature is not in this range (on empty kettle), refer to the CALIBRATING PROCEDURE on page #23.
21