PROBLEM:
Kettle Gets
Too Hot
The
kettle is working Yes properly.
Replace the
With the kettle empty and the temperature set at 10, is the surface temp
No
Does the kettle
continue to call for
heat (green light stays on) when the kettle reaches
No
Is there 115 vac to the primary of the
Is the resistance of
;the thermister
Yes 100,000 ohms + 10% at room temperature?
Yes
Is the resistance of the potentiometer
Replace the
No
thermister.
Replace the
gas valve.
No
ignition
transformer?
Yes
50,000 ohms at
the low setting and
0 ohms at high?
Yes
No
potentiometer
Replace the
Is there DC
Replace the
Relay
No
voltage to the coil
of the relay?
Yes
controller
Replace the
controller
PROBLEM: Red Add Water LED Stays On
Add the proper
amount of distilled No water and rust
inhibitor.
Clean or
replace water No probe.
Replace the
wire harness in No the trunion.
Does Red LED stay on after adding the proper amount of distilled water and rust inhibitor?
Yes
Is the red LED on
with probe grounded?
|
| Yes |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Does the red LED |
|
|
|
| |||
| stay on with a |
|
|
| Replace the | |||
| jumper between |
| Yes |
| ||||
|
|
| controller. | |||||
| pins 5 and 7 on |
|
|
| ||||
|
|
|
| |||||
|
|
|
|
| ||||
| the controller? |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
31