INSTALLATION

INSPECTION

Before unpacking visually inspect the unit for evidence of damage during shipping.

If damage is noticed, do not unpack the unit, follow shipping damage instructions.

SHIPPING DAMAGE

INSTRUCTIONS

If shipping damage to the unit is discovered or suspected, observe the following guidelines in preparing a shipping damage claim.

1.Write down a description of the damage or the reason for suspecting damage as soon as it is discovered. This will help in filling out the claim forms later.

2.As soon as damage is discovered or suspected, notify the carrier that delivered the shipment.

3.Arrange for the carrier's representative to examine the damage.

4.Fill out all carrier claims forms and have the examining carrier sign and date each form.

GENERAL

Installation of the kettle must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of product could cause injury or damage.

This equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL, and others. Many local codes exist, and it is the responsibility of the owner/installer to comply with these codes.

Observe all clearance requirements to provide proper make-up air flow. Do not obstruct the flow of combustion and ventilation air. Check rating plate to ensure that kettle has been equipped to operate with the type of gas available at the installation.

Dimensions and clearance specifications are shown on the SPECIFICATION DRAWING (see page #3-4).

CLEARANCE REQUIREMENTS

FOR CLEARANCE REQUIREMENTS (TO COMBUSTIBLE AND NONCOMBUSTIBLE WALLS) AND ASSEMBLY DETAILS REFER TO SPECIFICATION DRAWING ON PAGE #3.

INSTALLATION

Note: For clearance requirements, suggested drain location and assembly details refer to "SPECIFICATION DRAWING" on page #3.

1.Position the unit in it's permanent location, and level the unit by turning the adjustable feet.

2.Once positioned

and leveled,

 

 

 

 

 

 

4 7/8" (124mm)

 

 

 

permanently

120

 

 

120

secure the unit's

 

 

 

 

 

7/16"Ø, 3 HOLES

flanged feet to

 

 

 

 

 

 

 

 

 

 

ON 3 1/8" (80mm) B.C.D.

the floor using

FLANGED FOOT DETAIL

5/16" lag bolts

 

 

 

(REAR LEGS ONLY)

and floor

 

 

 

 

 

 

 

anchors

 

 

 

 

 

 

 

(supplied by the installer). Three bolts are required to secure each of the flanged feet.

3.Seal joints of flanged feet with a silicone sealant.

GAS

ENSURE THE GAS SUPPLY MATCHES THE KETTLE'S REQUIREMENTS AS STATED ON THE RATING PLATE.

It is recommended that a sediment trap (drip leg) be installed in the gas supply line. If the gas pressure exceeds 14” water column, a pressure regulator must be installed, to provide a maximum of 14” water column gas pressure to the gas control valve.

Connect the gas line to the manual valve located at the rear of the control box.

Installation must be in accordance with local codes and/or the National Fuel Gas Code ANSI Z223.1 Latest Edition (USA) or the latest Installation Codes for Gas Burning Appliances and Equipment CAN/ CGA B149.1 and CAN/ CGA B149.2 (Canada). Use a gas pipe joint compound which is resistant to L.P. gas. Test all pipe joints for leaks with soap and water solution. Ensure that the gas pressure regulator is set for the manifold pressure indicated on the gas rating plate.

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 kPa).

1

Page 4
Image 4
Cleveland Range KGL-25-T Inspection, Shipping Damage Instructions, General, Clearance Requirements, Installation, Gas

KGL-25-T, KGT-25, KGL-25, KGT-25-T, KCL-25-T specifications

Cleveland Range, a leader in commercial cooking equipment, presents an impressive lineup of steam cooking solutions with its models KCL-25-T, KGT-25-T, KGL-25, KGT-25, and KGL-25-T. These products are primarily designed for heavy-duty applications in restaurants, schools, and other foodservice environments, offering unmatched performance in steam cooking.

One of the most notable features across these models is their ease of use. Each unit boasts a digital control panel that allows operators to easily set time and temperature, ensuring that food is cooked to perfection every time. The intuitive design reduces the potential for operator error, making it an excellent choice for high-paced kitchens.

In terms of technology, Cleveland Range incorporates SmartSteam technology in these models. This innovative feature ensures an even distribution of steam within the cooking chamber, which enhances the cooking process and retains the nutritional value of food. The result is consistently moist, flavorful dishes with superior texture.

Durability is a key characteristic of the KCL-25-T, KGT-25-T, KGL-25, KGT-25, and KGL-25-T models. They are constructed with high-quality stainless steel, making them resistant to rust and corrosion, which is essential in a commercial kitchen environment. Their robust construction not only extends the lifespan of the equipment but also makes them easier to clean and maintain.

Energy efficiency is another significant advantage of these Cleveland Range models. Featuring insulated cooking chambers and efficient design, these steamers use less energy compared to traditional cooking methods. This translates into lower utility costs and reduces the kitchen’s carbon footprint, aligning with the broader goals of sustainability in the foodservice industry.

The KGT-25 and KGL-25 series particularly excel in versatility, allowing users to cook a wide range of menu items from vegetables to desserts. Their ability to accommodate full-size pans enhances their functionality, making them suitable for various food preparation needs.

In summary, Cleveland Range's KCL-25-T, KGT-25-T, KGL-25, KGT-25, and KGL-25-T models offer an exceptional combination of ease of use, advanced steam technology, durability, and energy efficiency. These features make them ideal solutions for foodservice operations that demand reliability and quality in steam cooking, catering to both large-scale and smaller culinary needs with superior performance.