PROBLEM: KGL-25
Does red light
come on when unit
| Does red light go |
Yes | off shortly after |
No
Add water to
Replace the
wire harness in
Kettle Won't
Heat
Replace |
|
| Is 16 VAC at the |
|
|
the on/off |
|
|
|
| |
Yes |
| secondary side of |
| No | |
switch (toggle |
|
| |||
|
| the transformer? |
|
| |
or rotary). |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
is first turned on?
No
Is 16 VAC
measured across Pins 9 and 10 on the controller?
unit is turned on? |
Yes
With the
potentiometer set Yes at 10, is 12 VDC at
the coil of the
relay?
jacket of Kettle.
| With a jumper | |
| across pins 5 and | |
| 7 on the controller, | |
No | ||
is there 12 VDC | ||
| ||
| across the coil of | |
| the DC relay? |
the trunion
|
|
| No |
| |
|
|
|
|
|
|
|
| With the jumper | |||
|
| removed and the | |||
|
| probe wire | |||
|
| grounded at the | |||
No |
| ||||
| probe, is 12 VDC | ||||
|
| ||||
|
| measured across | |||
|
| the coil of the DC | |||
|
| relay? |
No |
|
|
|
| Yes |
|
|
|
|
|
Replace the |
|
|
| Does the relay pull |
No |
|
| ||
relay. |
|
| in? | |
|
|
| ||
|
|
| ||
|
|
|
|
YesYes
Replace the | Yes |
transformer. |
|
Is there 115 VAC to the primary of the transformer?
Yes |
Does the
potentiomer have
a resistance of 50,000 ohms on low and 0 ohms at
Add water
Replace the
Is there 115 VAC to the primary of
high?
No
Replace the
No
Supply115 VAC to the kettle.
high limit.
No
the ignition
transformer?
Yes
Yes
Does the probe
have a resistance of 100,000 ohms + 10% at room temperature?
potentiometer
Replace the
Yes
controller
Replace the
ignition No transformer
Is there 24 VAC to
the ignition
Module?
No
Replace Probe
Yes
No
Replace
the Ignition
module.
Is there 24 VAC to the Gas valve for 4 Seconds?
Yes
Is there Gas to the
burner?
Yes
Replace the
No
gas valve
No
Is there Spark to the ignitor for 4 seconds.
Yes
If there
is spark and gas to the burner assmbly there should be flame. Check alighnment.
29