B. Semi-Automatic Cleaning of the Oven Chamber

NOTE: Do NOT press the Start/Stop key while using the Semi-automatic Cleaning process. This stops the cleaning process.

WARNING

The Semi-Automatic Cleaning process is designed to be started when the oven chamber temperature is at or below 158°F. Death, injury, and equipment damage can result from starting the Semi-Automatic Cleaning process when the oven chamber is above 158°F.

1.Before starting the Semi-Automatic Cleaning process, make sure the oven chamber is below 158°F by stopping all processes and pressing the Temperature key twice to view the actual temperature.

a.If the oven chamber is above 158°F then open the Combi door and wait 15 minutes.

b.Check the oven temperature again.

1)If the oven temperature is at or below 158°F then go to Step 2.

2)If the oven temperature is still above 158°F then wait 15 more minutes and check the oven chamber temperature. Repeat this step as needed until the oven chamber temperature is at or below 158°F and then go to Step 2.

2.See separate instruction sheet P/N 260AYM, “One-Hand Sprayer with Telescoping Wand,” for safety information, detailed instructions for using the sprayer, P/N 111598, and other information.

3.Always wear appropriate protective clothing and equipment when using this Sprayer, including protective gloves and goggles.

4.Close and latch the Combi door.

5.If the Combi is OFF, turn it ON.

6.Press the Smart Key. Various options appear in the display.

7.Use the Selector Dial to select “Cleaning” .

8.Confirm by pressing the Smart Key.

9.Confirm “Yes” with the Smart Key. The semi-automatic cleaning process starts.

10.Semi-automatic cleaning uses cooking modes to assist the cleaning process. The display shows the nominal values for the cooking modes.

a.The first step is Hot Air mode at 158°F for 10 minutes, followed by a Signal Tone.

11.After the first Signal Tone, open the oven door, and follow instruction sheet in P/N 260AYM to spray the oven chamber, drain, grills, plates etc. with original Convotherm by Cleveland CONVOClean.

12.Close and latch the Combi door and allow the CONVOClean to take effect. The Semi- Automatic Cleaning mode continues to run.

a.The second step is Steam mode at 86°F for 10 minutes, followed by a Signal Tone.

13.After the second Signal Tone, clean behind the fan guard and the fan area.

a.Release the quick-action locks on the oven racks and fan guard.

b.Swing the oven racks and fan guard into the oven chamber.

c.After cleaning, swing the oven racks and fan guard closed and fix it in place with the quick-action locks.

14.Close and latch the Combi door. The Semi-Automatic Cleaning mode continues automatically.

21

Page 24
Image 24
Cleveland Range OGB-6.20, OGS-6.20, OGS-10.10, OGB-10.10 manual Semi-Automatic Cleaning of the Oven Chamber