Cleveland Range OGB-10.10, OGB-6.20, OGS-6.20, OGS-10.10 manual e The steam circuit is energized

Models: OGB-10.10 OGS-10.10 OGS-6.20 OGB-6.20

1 101
Download 101 pages 10.21 Kb
Page 95
Image 95

The Hot Air Burner Control Module (N20) senses at least 1.5 micro amps DC from the flame sensor (P1) at terminal 3 of connector X2 and sends a signal from terminal 2 of connector X1 to terminal 12 of connector X15 on the Control Board (A10)

The heat circuit will remain energized until the cabinet set temperature is reached as sensed at probe B6.

eThe steam circuit is energized.

120 VAC is sent from terminal 4 of connector X12 on the Control Board (A10) to the coil of the Y3 solenoid allowing water to be thrown against the element until the bypass probe (B5) senses 183 degrees F.

The heat circuit will remain energized until the cabinet set temperature is reached

fIf the bypass probe (B5) drops below the set level the steam circuit will start again

gWhen the condensate box is heated to 140 degrees F at the B3probe, 120 VAC is sent from terminal 5 of connector X12 to the condenser valve (Y1) until the temperature drops.

hWhen the timer counts to 0 or the core temp probe (B10) reaches the set amount the cycle ends and the steam generator reverts to the standby temperature of 190- degree F.

88

Page 95
Image 95
Cleveland Range OGB-10.10, OGB-6.20, OGS-6.20, OGS-10.10 manual e The steam circuit is energized