Coleman 8200 Series, 8100 Series system manual Natural Gas Conversion Kit, Series M/N

Models: 8100 Series

1 16
Download 16 pages 10.17 Kb
Page 1
Image 1
Natural Gas Conversion Kit

Natural Gas Conversion Kit

For the following Coleman® Gas Barbecue Grills:

8100 Series (M/N 9992-643)

8200 Series (M/N 9992-644)

Connections must comply with local requirements and are the sole responsibility of the person performing

the work. A certified plumber must make connection to gas source. All codes must be followed.

Note: These instructions apply to more than one model grill. The parts included are designed for your specific grill. The illustrations may differ slightly from model to model.

IMPORTANT

Read this document carefully before attempting installation of this conversion kit. These instructions should be left with the consumer for future reference.

For the following Coleman® Gas Barbecue Grills: WARNING

This Natural Gas conversion Kit must be installed only by a qualified service technician.

Gas supply system must be installed in accordance with the U.S. National Fuel Gas Code.

This appliance and its individual shut off valve must be disconnected from the gas supply piping system during any system pressure test in excess of 1/2 PSI (3.5 KPA).

Use a system manual shut off valve to shut off the gas supply to this gas appliance before continuing with installation procedures.

8200 Series (M/N 9992-644) WARNING

If the information in this document is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Read the Coleman® Gas Barbecue Use, Care & Assembly Manual With Grill Lighting Instructions, before attempting installation of this conversion kit.

Manual background WARNING

• TURN OFF THE GAS SUPPLY!

DO NOT attempt to install this Natural Gas Conversion Kit

while the barbecue is in operation or is hot.

Manual background WARNING

A liquid propane tank, not connected for use with this gas barbecue,

shall not be stored in the vicinity of this or any other appliance.

Installation and provision for combustion and ventilation air must conform with the National Fuel Gas Code, ANSI Z223.1, or CAN/CGA-B149.1, Natural Gas Installation Code, or CAN/CGA-B149.2, Propane Installation Code.

Turn off LP tank and disconnect regulator from tank prior to servicing grill.