Coleman 9947A726 Connecting Type 1 L.P. Gas Cylinders, Leak Testing, ROTISSERIE cont, Danger

Models: 9947A726

1 20
Download 20 pages 48.47 Kb
Page 12
Image 12
STEP 20 ROTISSERIE (cont.)

Assembly/Set up (cont.)

STEP 20 ROTISSERIE (cont.)

Install Rotisserie Motor & Rotisserie Spit as shown.

Make sure Rotisserie Motor is placed on the right side of the grill.

NOTE: The Rotisserie Motor will appear to be upside down when installed correctly.

NOTE: The threaded Rotisserie handle is designed to be removable. When the Rotisserie is mounted on the grill, the han- dle will need to be removed to open or close the lid on the Left Side Burner. Replace the Rotisserie Handle before adjusting or removing the Rotisserie.

STEP 21 PROPANE CYLINDER SETUP

Install Propane Tank Base as shown.

Secure the Tank Base to the grill with one self-tapping screw. The hole location is in the front of the Tank Base Flange.

1 Required

STEP 22 INSTALLING IGNITION BOX

Connecting Type 1 L.P. Gas Cylinders

STEP 21 PROPANE CYLINDER SETUPWARNING

This procedure MUST be performed OUTDOORS only! Be sure L.P. cylinder valve is closed. Attach to Grill. Read and follow directions on the cylinder and fuel hose safety tags.

1 Required CAUTION

In the connection process, the grill side of the connection will seal on the back-check in the valve, resulting in a slight resist- ance. The connection requires about one-half to three-quar- ters additional turn to complete the connection. To disconnect, turn counterclockwise. Tighten by hand only. DO NOT use tools.

15

1.

Check that the cylinder valve is closed by turning the cylinder

 

knob clockwise to a full stop.

2.

Check that all the grill burner knobs are in the off position.

3.

Remove the protective caps from the cylinder valve and

 

coupling nut.

 

NOTE: The coupling nut connects to the large outside threads

 

on the valve outlet.

4.

Hold the regulator in one hand and insert the nipple into the

 

valve outlet. Be sure the nipple is centered in the valve outlet.

 

Hand-tighten the coupling nut, taking care not to cross-thread

 

the connection (see Fig. 15).

5.

Turn the coupling nut clockwise, tighten to a full stop.

6.

Check that the hose has no kinks or sharp bends and clears

 

areas that will become hot during use. Never put strain on the

 

hose where it joins a fitting.

 

NOTE: If you cannot complete the final connection, disconnect

 

the regulator and repeat steps 4 through 6. If you are still

 

unable to complete the connection, DO NOT use this valve and

Attach the color-coded wires.

Attach RED wires from main burners to terminals A1 and A2.

Attach GREEN wires from main burners to terminals B1 and B2.

Attach BLACK wires from main burners to terminals C1 and C2.

Attach BLACK wires from Side Burner to terminals D1 and D2.

Attach LARGE BLACK wires from Igniter Switch to the pair of terminals on the left side of the Ignition Box.

Install the 9-Volt battery with

positive (+) terminal as shown

12on Ignition Box.

Ignition Box

9-Volt Battery

regulator!

7. BEFORE lighting grill, check all connections for leaks using the

procedure as shown in Fig. 16 on pg. 13.

Leak Testing

STEP 22 INSTALLING IGNITION BOX DANGER

TO PREVENT FIRE OR EXPLOSION HAZARD:

NO SMOKING. DO NOT use or permit sources of ignition in the area while doing a leak test.

Perform leak tests outdoors only.

NEVER perform a leak test with fire or flame.

Page 12
Image 12
Coleman 9947A726 manual Connecting Type 1 L.P. Gas Cylinders, Leak Testing, ROTISSERIE cont, Propane Cylinder Setup, Danger