TABLE 9: Electrical Data - 3 Ø -
| Heater2 | Max. Static |
|
| Total Heat |
|
|
| KW Staging3 |
|
| |||
Models F*FP | & Min. CFM |
|
|
|
|
|
|
|
|
|
|
| ||
KW |
| MBH | W1 Only | W2 Only | W1 + W2 | |||||||||
Model |
| |||||||||||||
|
| Static | Tap | 208 |
| 240 | 208 | 240 | 208 | 240 | 208 | 240 | 208 | 240 |
024 | 2HK06501025B | 0.5 | Low | 7.5 |
| 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 |
030 | 2HK06501025B | 0.5 | Low | 7.5 |
| 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 |
2HK06501525B | 0.5 | High | 11.3 |
| 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | |
|
| |||||||||||||
036 | 2HK06501025B | 0.5 | Low | 7.5 |
| 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 |
2HK06501525B | 0.5 | High | 11.3 |
| 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | |
|
| |||||||||||||
040 | 2HK06501025B | 0.5 | Low | 7.5 |
| 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 |
2HK06501525B | 0.5 | High | 11.3 |
| 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | |
|
| |||||||||||||
042 | 2HK06501025B | 0.5 | Low | 7.5 |
| 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 |
2HK06501525B | 0.5 | Low | 11.3 |
| 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | |
|
| |||||||||||||
045 | 2HK06501025B | 0.5 | Med | 7.5 |
| 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 |
2HK06501525B | 0.5 | High | 11.3 |
| 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | |
|
| |||||||||||||
048 | 2HK06501025B | 0.5 | Med Low | 7.5 |
| 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 |
2HK06501525B | 0.5 | Med Low | 11.3 |
| 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | |
|
| |||||||||||||
060 | 2HK06501025B | 0.5 | Med | 7.5 |
| 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 |
2HK06501525B | 0.5 | Med | 11.3 |
| 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | |
|
|
1.Heat amps shown at 240V represents maximum heater rating.
2.Heaters are 3 Phase.
3.If first stage heat or 66 is connected to W1, otherwise refer to this table.
TABLE 10: Electrical Data - (For Single Source Power Supply) - Copper Wire 3 Ø -
| Heater2 |
|
| Field Wiring |
|
| ||
Models F*FP | Min. Circuit Ampacity | Max. O.C.P.3 Amps/Type | 75°C Wire Size - AWG | |||||
Model | ||||||||
|
| 208V | 240V | 208V | 240V | 208V | 240V | |
024 | 2HK06501025B | 41.2 | 46.5 | 45 | 50 | 8 | 8 | |
030 | 2HK06501025B | 42.2 | 47.4 | 45 | 50 | 8 | 8 | |
2HK06501525B | 42.2 | 47.4 | 45 | 50 | 8 | 8 | ||
| ||||||||
036 | 2HK06501025B | 43.1 | 48.2 | 45 | 50 | 8 | 8 | |
2HK06501525B | 43.1 | 48.2 | 45 | 50 | 8 | 8 | ||
| ||||||||
040 | 2HK06501025B | 42.2 | 47.4 | 45 | 50 | 8 | 8 | |
2HK06501525B | 42.2 | 47.4 | 45 | 50 | 8 | 8 | ||
| ||||||||
042 | 2HK06501025B | 44.2 | 49.1 | 45 | 50 | 8 | 8 | |
2HK06501525B | 44.2 | 49.1 | 45 | 50 | 8 | 8 | ||
| ||||||||
045 | 2HK06501025B | 42.8 | 47.9 | 45 | 50 | 8 | 8 | |
2HK06501525B | 42.8 | 47.9 | 45 | 50 | 8 | 8 | ||
| ||||||||
048 | 2HK06501025B | 48.3 | 53.9 | 50 | 60 | 8 | 6 | |
2HK06501525B | 48.3 | 53.9 | 50 | 60 | 8 | 6 | ||
| ||||||||
060 | 2HK06501025B | 48.3 | 53.9 | 50 | 60 | 8 | 6 | |
2HK06501525B | 48.3 | 53.9 | 50 | 60 | 8 | 6 | ||
|
1.Heat amps shown at 240V represents maximum heater rating.
2.Heaters are 3 Phase.
3.O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse.
12 | Unitary Products Group |