TABLE 3: Physical and Electrical Data |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Models F*FP |
|
|
| 024 |
| 030 |
| 036 | 040 |
| |||||
Blower - Diameter x Width |
|
|
| 10 x 6 |
|
| 10 x 8 |
|
| 10 x 8 |
| 10 x 8 | |||||
Motor |
| HP |
|
|
| 1/4 |
| 1/3 |
| 1/2 | 1/3 |
| |||||
| Nominal RPM |
|
|
| 1075 |
| 1075 |
| 1075 | 1075 |
| ||||||
|
|
|
|
|
|
|
| ||||||||||
Voltage |
|
|
|
|
|
|
|
|
|
|
| 208/230 |
|
|
|
| |
Amps |
| Full Load (208/230) |
|
| 1.6/1.4 (50 Hz:2.1) |
| 2.5 / 2.2 |
| 3.3/2.9 (50 Hz:2.3) | 2.5 / 2.2 |
| ||||||
| Locked Rotor (208/230) |
|
|
| 3.3 / 2.9 |
| 6.2 / 5.5 |
| 7.4 / 6.5 | 6.2 / 5.5 |
| ||||||
|
|
|
|
|
|
|
| ||||||||||
|
| Type |
|
|
|
|
|
| DISPOSABLE | OR PERMANENT |
|
|
| ||||
Filter1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Size |
|
|
| 16 x 20 x 1 |
| 16 x 20 x 1 |
| 20 x 20 x 1 |
| 20 x 20 x 1 | ||||||
|
| Permanent Type Kit |
|
|
| 1PF0601BK |
| 1PF0601BK |
| 1PF0602BK |
| 1PF0602BK | |||||
Shipping / Operating Weight (lbs.) |
|
|
| 98 / 93 |
| 105 / 100 |
| 115 / 109 | 121 / 115 |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Models F*FP |
|
|
| 042 |
| 045 |
| 048 | 060 |
| |||||
Blower - Diameter x Width |
|
|
| 10x8 |
|
| 10x10 |
|
| 11x10 |
| 11x10 | |||||
Motor |
| HP |
|
|
| 3/4 |
| 1/3 |
| 1.0 | 1.0 |
| |||||
| Nominal RPM |
|
|
| 1130 |
| 925 |
| 1050 | 1050 |
| ||||||
|
|
|
|
|
|
|
| ||||||||||
Voltage |
|
|
|
|
|
| 208/230 |
|
|
|
| 230 |
|
| |||
Amps |
| Full Load (208/230) |
|
|
| 4.4/3.8 |
| 3.0/2.7 |
| 7.6 | 7.6 |
| |||||
| Locked Rotor (208/230) |
|
|
| 11.9/10.3 |
| 4.8/4.1 |
|
| – |
| – | |||||
|
|
|
|
|
|
|
|
| |||||||||
|
| Type |
|
|
|
|
|
| DISPOSABLE | OR PERMANENT |
|
|
| ||||
Filter1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Size |
|
|
| 20 x 20 x 1 |
| 22 x 20 x 1 |
| 22 x 20 x 1 |
| 22 x 20 x 1 | ||||||
|
| Permanent Type Kit |
|
|
| 1PF0602BK |
| 1PF0603BK |
| 1PF0603BK |
| 1PF0603BK | |||||
Shipping / Operating Weight (lbs.) |
|
|
| 121/115 |
| 150/144 |
| 153/147 | 160/154 |
| |||||||
1. Field Supplied |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
TABLE 4: Electrical Data - Cooling Only (50 & 60 Hz) |
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| Total Motor Amps |
| Minimum Circuit Ampacity |
| Max. O.C.P.1 |
| Minimum Wire |
| ||||||
| Models F*FP |
| 60 Hertz |
|
|
|
| 60 Hertz |
|
|
| ||||||
|
|
|
|
|
|
| Amps/Type |
| Size A.W.G. |
| |||||||
|
|
|
| 208V |
| 240V |
| 208V |
| 240V |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| 024 |
| 1.6 |
| 1.5 |
| 2.0 |
|
| 1.8 |
|
| 15 |
| 14 |
| |
| 030 |
| 2.5 |
| 2.3 |
| 3.2 |
|
| 2.8 |
|
| 15 |
| 14 |
| |
| 036 |
| 3.3 |
| 3.0 |
| 4.2 |
|
| 3.7 |
|
| 15 |
| 14 |
| |
| 040 |
| 2.5 |
| 2.3 |
| 3.2 |
|
| 2.8 |
|
| 15 |
| 14 |
| |
| 042 |
| 4.4 |
| 4.0 |
| 5.5 |
|
| 4.8 |
|
| 15 |
| 14 |
| |
| 045 |
| 3.1 |
| 2.6 |
| 3.9 |
|
| 3.4 |
|
| 15 |
| 14 |
| |
| 048 |
| 7.6 |
| 7.6 |
| 9.5 |
|
| 9.5 |
|
| 15 |
| 14 |
| |
| 060 |
| 7.6 |
| 7.6 |
| 9.5 |
|
| 9.5 |
|
| 15 |
| 14 |
|
1. OCP = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse. TABLE 5: Conversion Table
KW & MBH Conversions - for Total Power Input Requirement
FOR
208V |
| 240V |
|
230V | OPERATION MULTIPLY | 240V | TABULATED KW & MBH BY |
|
|
|
|
220V |
| 240V |
|
|
|
|
|
.751
.918
.840
Unitary Products Group | 9 |