TABLE 11: Airflow Data for 230 Volt - Heat Pump Models1

 

Blower Motor

 

 

 

 

230 Volt

 

 

 

 

 

Models

 

 

 

CFM @ External Static Pressure - IWC

 

 

 

Speed

 

 

 

 

 

 

 

 

0.10

0.20

0.30

0.40

0.50

0.60

0.70

 

0.80

0.90

1.00

 

High

950

910

865

835

775

730

662

 

590

502

400

F4FP024H06T2*

Med

845

815

785

745

705

654

594

 

524

439

344

 

Low

650

630

605

575

540

508

450

 

383

285

158

 

High

1,270

1,210

1,150

1,085

1,015

946

862

 

769

645

502

F4FP030H06T2*

Med

1,050

1,040

995

930

855

804

714

 

624

494

364

 

Low

855

820

780

735

680

624

550

 

447

333

190

 

High

-

1,310

1,250

1,175

1,120

1,053

983

 

894

779

645

F4FP036H06T2*

Med

1,200

1,150

1,100

1,040

985

933

879

 

795

711

587

 

Low

1,060

1,015

970

925

860

809

740

 

661

572

453

 

High

1,270

1,210

1,150

1,085

1,015

946

802

 

769

645

502

F4FP040H06T2*

Med

1,050

1,040

995

930

855

804

714

 

624

494

364

 

Low

855

820

780

735

680

624

550

 

447

333

190

 

High

-

1,575

1,500

1,420

1,350

1,273

1,192

 

1,102

996

871

F4FP042H06T2*

Med

1,460

1,395

1,330

1,260

1,190

1,125

1,052

 

960

842

695

 

Low

1,250

1,200

1,155

1,100

1,050

1,001

931

 

851

751

631

 

High

1,575

1,535

1,475

1,390

1,310

1,245

1,147

 

1,030

897

735

F4FP045H06T2*

Med High

1,375

1,315

1,255

1,185

1,110

1,040

944

 

848

732

606

Med Low

1,210

1,160

1,110

1,050

980

921

844

 

737

640

533

 

 

 

Low

1,035

990

940

890

825

770

698

 

616

524

432

 

High

2223

2158

2090

2029

1929

1861

1788

 

1679

1594

1501

 

Med High

1948

1904

1801

1815

1777

1741

1681

 

1618

1539

1453

F5FP048H06T2*

Med

1741

1690

1649

1606

1564

1516

1476

 

1436

1387

1353

 

Med Low

1499

1454

1415

1370

1328

1269

1228

 

1191

1132

1093

 

Low

1286

1233

1177

1142

1092

1039

987

 

960

888

842

 

High

2195

2145

2070

2008

1920

1852

1754

 

1663

1570

1462

 

Med High

1938

1899

1873

1824

1791

1724

1679

 

1603

1521

1420

F5FP060H06T2*

Med

1726

1681

1641

1607

1560

1517

1485

 

1433

1402

1349

 

Med Low

1525

1483

1441

1383

1356

1291

1253

 

1208

1169

1123

 

Low

1306

1254

1204

1160

1114

1061

1008

 

980

914

876

 

High

2,285

2,195

2,105

2,015

1,950

1,845

1,770

 

1,685

1,590

1,485

F4FV060H06T2*

Med.

2,125

2,020

1,910

1,805

1,705

1,597

1,491

 

1,386

1,280

1,175

 

Low

1,655

1,605

1,550

1,500

1,450

1,398

1,326

 

1,245

1,153

1,052

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Air flow data shown above 0.50” W.C. external static pressure is for REFERENCE ONLY. Maximum allowable external static when electric heat is used is limited to 0.50” W.C. Maximum allowable external static pressure may also be limited by minimum CFM requirements for proper Heat Pump operation.

1. Includes Return Air Filter and Largest Electric Heater.

All F*FP series air handler units are UL Listed up to 0.50" w.c. external static pressure, including air filter, wet coil, and largest KW size heater.

Unitary Products Group

13

Page 13
Image 13
Coleman F*FP Airflow Data for 230 Volt Heat Pump Models1, High 950 910, 835 775 730, 590 502 400 F4FP024H06T2 Med 845 815

F*FP specifications

The Coleman F*FP, an innovative product from the renowned outdoor gear manufacturer Coleman, represents a significant leap forward in portable lighting solutions. Designed for outdoor enthusiasts, campers, and emergency preparedness, this compact device merges functionality with cutting-edge technology.

One of the standout features of the Coleman F*FP is its impressive brightness, which can easily illuminate small campsites or provide adequate light for activities such as cooking or reading after sunset. With adjustable brightness settings, users can customize the light output according to their specific needs, effectively conserving battery life when full brightness isn’t necessary.

The Coleman F*FP incorporates advanced LED technology, ensuring longevity and efficiency. Unlike traditional incandescent bulbs, the LEDs offer a much longer lifespan and consume significantly less power, making them an ideal choice for outdoor use where access to electricity may be limited. This energy-efficient design makes the F*FP not only cost-effective but also environmentally friendly.

Portability is another key characteristic of the Coleman F*FP. The device is lightweight and compact, making it easy to pack and transport, whether you're heading on a weekend camping trip or preparing for an emergency situation. It typically features a built-in handle or a hook for easy hanging, allowing for versatile placement in tents, trees, or outdoor structures.

Durability is paramount when it comes to outdoor equipment, and the Coleman F*FP does not disappoint. Constructed with weather-resistant materials, it can withstand various environmental conditions, from rain to dust, ensuring reliable performance and longevity. This rugged construction makes it a trustworthy companion for any outdoor adventure.

The F*FP also includes user-friendly features such as easy-to-navigate controls and battery indicators. Some models may offer rechargeable options, reducing the need for disposable batteries and enhancing sustainability.

In summary, the Coleman F*FP stands out in the realm of outdoor lighting solutions. Its impressive brightness, energy-efficient LED technology, portability, and durable construction make it an essential tool for adventurers and a sensible choice for emergency preparedness. With the Coleman F*FP in tow, users can enjoy peace of mind and a well-lit experience in the great outdoors.