3-56 Diagnostic Tools
DAAD Diagnostic Messages
continued
Message Description Recommended Action
Drive (bay) X
firmware
needs
upgrading
Firmware on this physical drive
is below the latest
recommended version.
Run the Options ROMPaq Utility to upgrade
the drive firmware to the latest revision.
Drive (bay) X
has invalid
M&P stamp
Physical drive has invalid
monitor and performance data.
Run the System Configuration Utilit y to
properly initialize this drive.
Drive X
indicates
position Y
Message indicates which
physical drive appears to be
scrambled or in a drive bay other
than the one for which it was
originally configured.
Examine the graphical drive representation on
DAAD to determine proper drive locations.
Remove drive X and place it in drive position
Y. Rearrange the drives according to the
DAAD instructions.
Drive (bay) X
RIS copy
mismatch
The copies of the RIS on this
drive do not match.
This drive may need to be replaced. Check for
other errors.
Drive (bay) X
upload code
not readable
An error occurred while DAAD
was trying to read the upload
code information from this drive.
If there were multiple error s, this drive may
need to
be replaced.
Drive (bay) X
has loose
cable
The array controller could not
communicate with this drive at
power-up. This drive has not
previously failed.
Check all cable connections first. The cables
could be bad, loose, or disconnected. Turn on
the system and attempt to reconnect
data/power cable to the drive. If this does not
work, replace the cable. If that does not work,
the drive may need to be replaced.
Drive (bay) X
is a
replacement
drive
This drive has been replaced.
This message displays if a drive
is replaced in a fault tolerant
logical volume.
If the replacement was intentional, allow the
drive
to rebuild.
Drive (bay) X
is a
replacement
drive marked
OK
This drive has been replaced
and marked OK by the firmware.
This may occur if a drive has an
intermittent failure (for example,
if a drive has previously failed,
then when DAAD is run, the
drive starts working again).
Replace the drive.
Drive (bay) X
is failed
The indicated physical drive has
failed.
Replace this drive.
Drive (bay) X
has insufficient
capacity for its
configuration
Drive has insufficient capacity to
be used in this logical drive
configuration.
Replace this drive with a larger capacity drive.