Manuals
/
Brands
/
Computer Equipment
/
Computer Monitor
/
Compaq
/
Computer Equipment
/
Computer Monitor
Compaq
1850R manual
1
1
203
203
Download
203 pages, 5.28 Mb
Compaq ProLiant 1850R
Setup and Installation Guide
Second Edition (January 1999)
Part Number 333172-002
Compaq Computer Corporation
Contents
Main
Notice
Compaq ProLiant 1850R Setup and Installation Guide
Contents
About This Guide
Chapter 1
Compaq ProLiant 1850R Features
Chapter 2
Server Installation Overview
Chapter 3
Installing Hardware Options
Chapter 4
Cabling Guidelines
Chapter 5
Server Configuration and Utilities
Chapter 6
Integrated Management Log
Appendix A
Regulatory Compliance Notices
Page
Appendix G
Updating LAN Drivers
Index
Page
About This Guide
Text Conventions
Symbols in Text
!
Symbols on Equipment
Rack Stability
!
Getting Help
Compaq Web Site
Telephone Numbers
Chapter 1
Compaq ProLiant 1850R Features
ProLiant 1850R
Page
ProLiant 1850R Front View
Page
1-5
Table 1-2 Compaq ProLiant 1850R Wide Ultra2 Front Components
Thumbscrew Identification
Table 1-3 Front Bezel Thumbscrew Locations
1-7
ProLiant 1850R Rear Components
The following figure shows the components on the rear of the ser ver.
Table 1-4 Rear Panel Components
1-8 Compaq ProLiant 1850R Features
Locating ProLiant 1850R Server Internal Components
Inside View of the ProLiant 1850R Server
Table 1-5 ProLiant 1850R Internal Components
Industry Support
Standard Features
Processors and Processor Power Modules
Page
Disk Controller
Integrated Network Controller
Mass Storage
Wide Ultra SCSI-3 Models
Table 1-6 Description of ProLiant 1850R Media Bays
Page
Table 1-7
Description of ProLiant 1850R Wide Ultra2 Media Bays
Standard Interfaces
Video
ROM
Hot Plug Power Supply
Warranty
Server Management
and Configuration
Default Configuration
Compaq SmartStart
Server Management
Fault Tolerance
Compaq Insight Manager
Compaq System Configuration Utility
Automatic Server Recovery-2 (ASR-2)
Compaq Integrated Remote Console
Front Panel Status LEDs Description
Hot-Plug Power Supply LED
RJ-45 LED Indicators
Security Features
Diagnostics
Pre-Failure Warranty
Insight Manager Alert
Chapter 2
Server Installation Overview
Page
Server Warnings and Precautions
Page
Temperature Requirements
Table 2-1 Rack Internal Temperature Maximums
Page
Installation Sequence
Page
Page
Bag of screws
Installing Expansion Boards and
Other Major Hardware Options
Preparing the Rack Mounting Brackets and Slide Rail Assemblies
Slide Rail Assembly Components
Attaching the Outer Bracket Rail to the Rack Mounting Bracket
Page
Page
Page
Page
Page
Attaching the Rack Mounting Bracket and Slide Assembly to the Rack
Measuring with the Template
Inserting Cage Nuts in the Rack Frame
Attaching the Rack Mounting Bracket Assembly to the Rack
Page
Page
Attaching Server Rails to the Server
Attaching the Server Bracket to the Server
Loading the Rack Server
Page
Attaching the Cable Management Arm
Page
Connecting the Power Cord and Peripheral Devices
2-31
Table 2-2 Rear Panel Connectors/LED
Page
Powering Up the Server
Configuring the Server with Compaq SmartStart
Page
Using the Power Switch
Using Diagnostics Tools
Registering Your Server
Routine Maintenance
Optional Installation Service
Chapter 3
Installing Hardware Options
Accessing Non Hot-Plug Areas
Accessing Processors, Memory Sockets, and System Board
Page
Installing a Processor and Processor Power Module
Table 3-1 Processor and Processor Power Module slot locations
Page
Installing a Processor Power Module
Adding Memory to the ProLiant 1850R Server
Table 3-2 DIMM Option Kit Part Numbers
Table 3-3 DIMM Socket Identification
Maximum Memory Configuration
Installing DIMMs
Identifying Expansion Slots
Page
Installing an Expansion Board
Page
Removing Expansion Board Shipping Bracket
Replacing the Riser Board and Riser Board Brace
Replacing the Riser Board and Riser Board Brace
Page
Installing Removable Media Devices
General Installation Guidelines
SCSI ID Settings for Compaq Hard Drives
Table 3-4 SCSI ID Settings
Installing ProLiant 1850R Mass Storage Devices
Page
Replacing the 1.44-MB Diskette Drive (Floppy Drive)
Removing the 1.44-MB Diskette Drive (floppy drive)
Page
Installing the 1.44-MB Diskette Drive (Floppy Drive)
Enabling the Power Switch Security Feature
To enable the power switch security feature:
Page
Replacing the CD-ROM Drive
Removing the CD-ROM Drive
Installing the CD-ROM Drive
Attaching Mass Storage Devices
Installing External Storage Devices
Installing a 3.5-Inch Drive into a 5.25-Inch Drive Bay
Page
Page
Installing a Half-Height Device
Page
Installing a Full-Height Device (DLT Tape Drive)
Page
Accessing the Hot-Plug Areas
Installing Hot-Plug Wide Ultra SCSI-3 Drives
Installing Hot-Plug Wide Ultra2 SCSI Drives
SCSI ID Numbers for Wide Ultra SCSI-3 Models
Page
Installing a Hot-Plug Redundant Power Supply
Page
Page
Page
Chapter 4
Cabling Guidelines
Connecting the Power Cord and Peripheral Devices
4-2 Cabling Guidelines
Rear Panel Connectors
The illustration below shows the connectors and switches for the ProLiant 1850R server.
Table 4-1 Rear Panel Connectors
Internal Connectors
Table 4-2 Important Connectors
Cabling the Servers Rear Panel Cables
Page
Additional Mass Storage Devices
Guidelines
Contents
Table 4-3 ProLiant 1850R Server Cables and Server Cable Kit Contents
SCSI Cable Connectors
SCSI Cabling Guidelines
Determining the Cables you Need
Internal SCSI Cabling Guide For Compaq ProLiant 1850R Servers
4-13
Internal Cabling
Table 4-4 Internal Cabling for the Compaq ProLiant 1850R
4-14 Cabling Guidelines
Internal Cabling for the Compaq ProLiant 1850R Continued
4-15
External Cabling for Primary Storage Only
Table 4-5 External Cabling for Primary Storage Only
4-16 Cabling Guidelines
External Cabling for Secondary Storage
Table 4-6 External Cabling for Secondary Storage
ProLiant 1850R Cabling Examples
Connecting an Array Controller to the Hot-Plug Drive Cage Backplane Board
Page
ProLiant 1850R Maximum External Storage Cabling
Connecting Three Array Controllers For Maximum External Storage Capability
Chapter 5
Server Configuration and Utilities
Compaq System Configuration Utility
Resolving Resource Conflicts
Starting the System Configuration Utility
System Configuration Utility Main Menu
System Configuration Menu
Configuring Hardware
1. Important System Configuration Information
2. Add or Remove Boards
3. View or Edit Details
4. Examine Required Switches
5. Save and Exit
Drive Array Configuration
Setting Power-On Defaults
System Partition
Creating a New System Partition
Verifying the System Partition
Upgrading the System Partition
Configuration Backup
Configuration History Files
Table 5-1 System Configuration History Log Files
Boards Automatically
SMP Operating System Support
Loading Compaq Device Drivers
Novell Device Drivers from Compaq
Manual Installation
Microsoft Windows NT Device Drivers from Compaq
Manual Installation
SCO OpenServer and SCO UnixWare
Device Drivers from Compaq
Special Considerations
IBM OS/2 Device Drivers from Compaq
Manual installation
Retail Installation
SunSolaris Device Drivers from Compaq
Banyan Vines Device Drivers from Compaq
Manual installation
Diagnostics and Other Utilities
Controller Naming Conventions
Table 5-2 Controller Driver Naming Conventions
Page
Chapter 6
Integrated Management Log
Multiple Ways of Viewing the Log
Compaq Insight Manager
Viewing the Event List
Printing the Event List
Compaq Survey Utility
6-4 Compaq Integrated Management Log
List of Events
Table 6-1 Event Messages
6-5
Event Messages
Appendix A
Regulatory Compliance Notices
Federal Communications Commission Notice
Modifications
Cables
Declaration of Conformity for products marked with the FCC logo -
United States only
Canadian Notice
Japanese Notice
Avis Canadien
European Union Notice
Taiwan Notice Laser Devices
Laser Safety Warnings
Compliance with CDRH Regulations
Compliance with International Regulations
Laser Product Label
Laser Information
Battery Replacement Notice
Appendix B
Electrostatic Discharge
Grounding Methods
Page
Appendix C
Power Cord Set Requirements
General Requirements
Country-Specific Requirements
Table C-1 Power Cord Set Requirements - By Country
Appendix D
Installing a New Battery
System Board Battery Replacement
Installing the System Board Battery
Page
Page
Appendix E
Switches and Jumpers
Setting System Board Switches
System Configuration Switch Settings (S1 Settings)
E-3
Processor Switch Settings
The following table defines the function for each switch setting on SW1.
Table E-2 Processor Switch Settings
NIC Operating Mode
SCSI Device Jumper Settings
Table E-3 SCSI Device Jumper ID Settings
Page
F-1
Appendix F
Specifications and Connector Interfaces
ProLiant 1850R Specifications
Table 1-1 ProLiant 1850R Specifications
Connector Interfaces
Appendix G
Updating LAN Drivers
Introduction
Operating Systems Requiring Special LAN Driver Installation
Installing NetWare Lan Drivers
For Novell Products (NSSD) version 3.22A diskettes
:\cpqsupsw\nssd\network
LAN Driver Update Procedure intraNetWare for Small Business from Compaq
Setup intraNetWare for Small Business from Compaq
Page
LAN Driver Update Procedure NetWare for Small Business 4.11
Setup NetWare for Small Business 4.11
LAN Driver Update Procedure For NetWare 3.2
Installing Windows NT 4.0 LAN Drivers
For Windows NT 4.0 (NTSSD) version 2.08 diskettes
LAN Driver Installation Procedure for Window NT 4.0
Installing IBM OS/2 LAN Drivers
LAN Driver update procedure for IBM Operating Systems
Installing Banyan VINES LAN Driver
LAN Driver update procedure for Banyan Vines versions 6.X, 7.X and 8.x.
Page
Installing SunSoft Solaris 2.5.1, 2.6, and Later Versions (Intel Platforms) LAN Drivers
Index
Symbols
Numbers
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
R
Page
S
Page
T
U
V
W