3-42 Diagnostic Tools

SCSI Tape Drive Test Error Codes
The 6700 series of Diagnostic error codes identifies failures with tape cartridges, tape drives,
media changers, tape drive cabling, adapter boards, or the system board assembly. Corrective
action may require replacement of a tape cartridge, tape drive, media changer, tape drive
cabling, adapter board, or the system board assembly.

Table 3-18

SCSI Tape Drive Test Error Codes

Error Code Description Recommended Action
6700-xx
6706-xx
6709-xx
6728-xx
SCSI Tape ID drive types test failed.
SCSI Disk SA/Media test failed.
SCSI Disk Erase tape test failed.
Media load/unload test failed.
The following steps apply to error codes
6700-xx through 6728-xx:
1. Run the System Configuration Ut ility
and verify the drive type.
2. Replace the SCSI Tape drive signal
and power cables and retest.
3. Replace the SCSI controller and
retest.
4. Replace the SCSI Tape drive and
retest.
5. Replace the system board and retest.
Server Manager/R Board Test Error Codes
The 7000 series of Diagnostic error codes identifies failures with the Server Manager/R board.
Corrective action may require replacement of the Server Manager/R board, the Integrated
2400-baud modem, voice ROM, or the battery on the Server Manager/R board.

Table 3-19

Server Manager/R Board Test Error Codes

Error Code Description Recommended Action
7000-11
7000-12
7000-13
7000-14
7000-15
7000-21
7000-22
7000-23
7000-24
Processor (80186 Timer).
Processor (80186 Registers).
Processor (Watch Dog Timer).
Processor (8570 RAM).
Processor (8570 RTC).
Memory.
Memory Write/Read.
Memory Address.
Memory Refresh Alert.
For error codes 7000-11 through
7000-46, replace the Server Manager/R
board
and retest.
continued