A Check of the Supplied Items and the Names of the Parts

Names and Functions of the Parts (Operation Panel)

INPUT

ROTATION FREEZE OFF FREEZE/CAPTURE

ON/STANDBY

 

LAMP/COVER

 

TEMP

TRANSFER

 

1

2

3

4

5

6

7

8

1.ON/STANDBY LED

Lit red during standby and lit green when the projection lamp is on. See Page E-21.

2.LAMP/COVER LED

Lit green during projection. Lit red when the air filter or lamp unit cover is not in place.

At the time of the projection lamp lighting operation, the LED flashes for about 6 seconds and then lights green.

At the time of a projection lamp lighting failure, the LED flashes green. (The flashing interval when the projection lamp is off will be longer than when the LED flashes at other times.)

When the projection lamp is off, the LED flashes green for 60 seconds and then goes off.

When the projection lamp has been used in excess of 1,900 hours, the LED flashes red; when use exceeds

2,000 hours the LED is lit a steady red. See Page E-45.

3.TEMP LED

When the internal temperature has risen excessively, the LED flashes red for 10 seconds, then is lit a steady red. See Page E-45.

LED List

 

LED State

 

Significance

 

ON/

LAMP/

TEMP

 

STANDBY

COVER

 

 

 

 

 

Off

Off

Off

AC power OFF

 

Red

Off

Off

Standby

 

 

Flashing

 

Standby to start of projec-

Normal

Green

Off

tion

condition

green

E n d o f p r o j e c t i o n t o

 

 

 

 

 

 

standby

 

Green

Green

Off

Projecting

 

 

 

 

Lamp cover open

Power

Red

Red

Off

Lamp burned out

has been

 

switched

L a m p u s a g e e x c e e d s

 

 

 

OFF

 

 

 

2,000 hours

because of

Red

Orange

Off

Internal problem

the alarm

Red

Off

Red

Temperature fault

 

Fan fault

 

 

 

 

 

Green

Flashing

Off

L a m p u s a g e e x c e e d s

 

red

1,900 hours

Alarm

 

 

Green

Green

Flashing

Abnormal temperature

sounding

red

warning

 

 

 

 

4.ON/STANDBY Button

Switches the power of the projector on or off (standby mode).

Only this button is effective when the projection lamp is off. See Page E-21.

5.INPUT Button

Press this to switch the input.

The input switches as follows: OHP → PC → VIDEO or OHP → VIDEO (D4) → VIDEO.

See page E-23.

6.ROTATION/TRANSFER Button

At OHP selection: Changes over the direction of the pro- jection screen every 90 degrees (clockwise). The changed- over screen is displayed according to the lateral axis.

See page E-23.

When a USB cable is connected, the images stored in the internal memory are transferred to the computer. (This function is only available on the iP-40SE.)

See pages E-26 and 32.

7.FREEZE OFF Button

Cancels the still image mode.

This is used when checking the projection screen while moving the document.

See Page E-27.

8.FREEZE/CAPTURE Button

Makes the projection screen image into a still image. In the OHP mode, the image is stored in internal memory as a thumbnail.

When the SD memory card has been inserted, the image is saved in the SD memory card. *

*Only for iP-40SE. See Page E-26.

E-11