Compaq MSB900L user manual Digital-Logic Ag, Only for factory and POD-Diagnostic use

Models: MSB900 MSB900L

1 66
Download 66 pages 9.24 Kb
Page 51
Image 51
Only for factory and POD-Diagnostic use.

 

DIGITAL-LOGIC AG

 

MSB900/L Detailed Technical Manual V1.0

 

X101 PCI-104 BUS Interface

 

 

 

 

 

 

 

 

 

 

 

 

Pin

A

B

C

D

 

 

 

 

 

 

 

 

 

1

GND/5.0V KEY2

Reserved

+5

AD00

 

 

2

VI/O

AD02

AD01

+5V

 

 

3

AD05

GND

AD04

AD03

 

 

4

C/BE0*

AD07

GND

AD06

 

 

5

GND

AD09

AD08

GND

 

 

6

AD11

VI/O

AD10

M66EN

 

 

7

AD14

AD13

GND

AD12

 

 

8

+3.3V

C/BE1*

AD15

+3.3V

 

 

9

SERR*

GND

SB0*

PAR

 

 

10

GND

PERR*

+3.3V

SDONE

 

 

11

STOP*

+3.3V

LOCK*

GND

 

 

12

+3.3V

TRDY*

GND

DEVSEL*

 

 

13

FRAME*

GND

IRDY*

+3.3V

 

 

14

GND

AD16

+3.3V

C/BE2*

 

 

15

AD18

+3.3V

AD17

GND

 

 

16

AD21

AD20

GND

AD19

 

 

17

+3.3V

AD23

AD22

+3.3V

 

 

18

IDSEL0

GND

IDSEL1

IDSEL2

 

 

19

AD24

C/BE3*

VI/O

IDSEL3

 

 

20

GND

AD26

AD25

GND

 

 

21

AD29

+5V

AD28

AD27

 

 

22

+5V

AD30

GND

AD31

 

 

23

REQ0*

GND

REQ1*

VI/O

 

 

24

GND

REQ2*

+5V

GNT0*

 

 

25

GNT1*

VI/O

GNT2*

GND

 

 

26

+5V

CLK0

GND

CLK1

 

 

27

CLK2

+5V

CLK3

GND

 

 

28

GND

INTD*

+5V

RST*

 

 

29

+12V

INTA*

INTB*

INTC*

 

 

30

-12V

Reserved

Reserved

GND/3.3V KEY2

 

Notes:

1.The shaded area denotes power or ground signals.

2.The KEY pins are to guarantee proper module installation. Pin-A1 will be removed and the female side plugged for 5.0V I/O signals and Pin-D30 will be modified in the same manner for 3.3V I/O. It is highly recommended that both KEY pins (A1 and D30) be electrically connected to GND for shielding.

DLAG boards have them as NC (not connected).

X110 LPC-Port

Only for factory and POD-Diagnostic use.

Pin

Signal

Pin

Signal

 

 

 

 

1

VCC 3.3V

2

LAD0

3

LFrame#

4

LAD1

5

PCI_RST#

6

LAD2

7

FWH_TBL#

8

LAD3

9

VCC 5V

10

PCI_RST#

11

LPC_Clock

12

nc

13

Ground

14

FWH_Control

51

Page 51
Image 51
Compaq MSB900L user manual Digital-Logic Ag, Only for factory and POD-Diagnostic use