Removal and Replacement Preliminaries

Nonconductive plastic bags, tubes, or boxes

Metal tote boxes

Electrostatic voltage levels and protective materials

Table 4-1 shows how humidity affects the electrostatic voltage levels generated by different activities.

Table 4-1

Typical Electrostatic Voltage Levels

 

 

Relative Humidity

 

 

 

 

 

 

 

 

 

Event

10%

 

40%

 

55%

 

 

 

 

 

 

 

 

Walking across carpet

35,000

V

15,000

V

7,500

V

 

 

 

 

 

 

 

Walking across vinyl floor

12,000

V

5,000

V

3,000

V

 

 

 

 

 

 

 

Motions of bench worker

6,000

V

800

V

400

V

 

 

 

 

 

 

 

Removing DIPS from plastic tube

2,000

V

700

V

400

V

 

 

 

 

 

 

 

Removing DIPS from vinyl tray

11,500

V

4,000

V

2,000

V

 

 

 

 

 

 

 

Removing DIPS from Styrofoam

14,500

V

5,000

V

3,500

V

 

 

 

 

 

 

 

Removing bubble pack from PCB

26,500

V

20,000

V

7,000

V

 

 

 

 

 

 

 

Packing PCBs in foam-lined box

21,000

V

11,000

V

5,000

V

A Product can be degraded by as little as 700 volts.

Maintenance and Service Guide

4–7

Page 125
Image 125
Compaq N800C manual Typical Electrostatic Voltage Levels, Relative Humidity Event 10% 40% 55%