CONAIR

MARTIN

11.1.2Pause/pulse relay when emptying with Air-veyor

In those cases when emptying of the granule bin with an air veyor has been chosen, the pause/pulse relay should be cancelled to prevent a glut in the granule bin.

When delivered, the relay is preset as follows:

T1 = range 1 - 10 m

A

T2 = range 6 - 60 s

 

where

 

Pause time T1 (the time the air

 

veyor is idle) is selected using

 

switches (A) and (B). Then the

 

time is set using the handwheel

 

Toff = T1.

C

Delay time interval T2 (the time

 

the air veyor is working) is

 

selected using switches (C) and

 

(D). Then the time is set using

 

the handwheel Ton = T2.

 

B

D

A Setting of: seconds, minutes or hours

B Setting of multiples: x0.1 or x1

C Setting of: seconds, minutes or hours

D Setting of multiples: x0.1 or x1